Characterization Of Structures Of Equivalent Tissue With a Pixel Detector

Abstract

Research using hybrid pixel detectors in medical physics is on the rise. Timepix detectors have arrays of 256 × 256 pixels with a resolution of 55 µm. Here, and by using Timepix counts instead of Hounsfield units, we present a calibration curve of a Timepix detector analog to those used for CT calibration. Experimentation consisted of the characterization of electron density in 10 different kinds of tissue equivalent samples from a CIRS 062M phantom (lung, 3 kinds of bones, fat, breast, muscle, water and air). Radiation of the detector was performed using an orthodontic X-ray machine at 70 KeV and .06 second of tube current with a purpose-built aluminum collimator. Data acquisition was performed at 1 frame per second and taking 3 frames per phantom. We were able to find a curve whose behavior was similar to others already published. This will lead to the verification of the usage of Timepix for identification of different tissues in an organ.

Authors and Affiliations

M. C. Grados Luyando, B De Celis-Alonso, E. Moreno-Barbosa, M. I. Martinez Hernandez, J. M. Hernandez Lopez, G. Tejeda Munoz

Keywords

Related Articles

Possible Alpha and 14C Cluster Emission From Hyper Radium Nuclei in The Mass Region A = 202-235

The possibilities for the emission of 4He and 14C clusters from hyper 202 235ΛRa are studied using our Coulomb and proximity potential model (CPPM) by including the lambda-nucleus potential. The predicted half lives show...

Mass Attenuation Coefficient Measurements of Some Nanocarbon Allotropes: A New Hope for Better Low Cost Less-Cumbersome Radiation Shielding Over A Wide Energy Range

The mass attenuation coefficients of graphene, MWNTs and, SWNTs have been measured for gamma energy range 356 to 1332 keV from the radioactive sources 60Co, 133Ba and 137Cs using a well calibrated gamma ray spectrometer...

Evolution of Shapes and Search for Shape Coexistence in Sd-Shell Nuclei

A detailed and systematic study has been performed using state-dependent Relativistic Mean-Field plus BCS (RMF+BCS) approach to investigate shape evolution for even-even isotopes of Ne, Mg, Si and S. We perform quadrupol...

Extensions of Natural Radioactivity to 4th-Type and of the Periodic Table to Super-heavy Nuclei: Contribution of Raj K Gupta to Cold Nuclear Phenomena.

We have studied here the contribution of Indian Scientists associated with Prof. Raj K. Gupta to cold nuclear phenomena during the last almost four decades, which led to the discovery of fourth kind of natural radioactiv...

Radio-Optically- and Thermally Stimulated Luminescence of Zn(BO2)2:Tb3+ exposed to Ionizing Radiation

The optical absorption of zinc tetraborate at different concentrations of the terbium impurity (0, 0.5, 1, 2, 4, 8 mol%) was analyzed. The radioluminescence (RL) emission spectra was obtained after beta irradiation of a...

Download PDF file
  • EP ID EP595705
  • DOI 10.15415/jnp.2017.51008
  • Views 215
  • Downloads 0

How To Cite

M. C. Grados Luyando, B De Celis-Alonso, E. Moreno-Barbosa, M. I. Martinez Hernandez, J. M. Hernandez Lopez, G. Tejeda Munoz (2017). Characterization Of Structures Of Equivalent Tissue With a Pixel Detector. Journal of Nuclear Physics, Material Sciences, Radiation and Applications, 5(1), 79-89. https://europub.co.uk/articles/-A-595705