Characterization Of Structures Of Equivalent Tissue With a Pixel Detector

Abstract

Research using hybrid pixel detectors in medical physics is on the rise. Timepix detectors have arrays of 256 × 256 pixels with a resolution of 55 µm. Here, and by using Timepix counts instead of Hounsfield units, we present a calibration curve of a Timepix detector analog to those used for CT calibration. Experimentation consisted of the characterization of electron density in 10 different kinds of tissue equivalent samples from a CIRS 062M phantom (lung, 3 kinds of bones, fat, breast, muscle, water and air). Radiation of the detector was performed using an orthodontic X-ray machine at 70 KeV and .06 second of tube current with a purpose-built aluminum collimator. Data acquisition was performed at 1 frame per second and taking 3 frames per phantom. We were able to find a curve whose behavior was similar to others already published. This will lead to the verification of the usage of Timepix for identification of different tissues in an organ.

Authors and Affiliations

M. C. Grados Luyando, B De Celis-Alonso, E. Moreno-Barbosa, M. I. Martinez Hernandez, J. M. Hernandez Lopez, G. Tejeda Munoz

Keywords

Related Articles

Investigation of the Saturation of Elemental Concentration in the Depth Profile of Low Energy Silver Ion Implants in Silicon

For the efficient absorption of light in a broad wavelength band, Si photovoltaic devices require a high concentration of metal atoms at a shallow depth up to a few 10s of nm in the Si substrates. Low energy (< 50 keV) i...

Analysis and characterization of neutron scattering of a Linear Accelerator (LINAC) on medical applications.

In several theoretical and experimental studies, the topic of the undesirable generation of photoneutrons in rooms where a linear accelerator (LINAC) operates has been discussed. When energies above 10 MeV are used to pr...

Synthesis of MgB4O7:Dy3+ and Thermoluminescent Characteristics at Low Doses of Beta Radiation

The synthesis and thermoluminescent characteristics of dysprosium-doped MgB4O7 are analyzed. The phosphor at different concentrations (0, 0.1, 0.5, 1, 2 and 4 mol%) of the dopant was prepared by the solution-assisted met...

Density Functional Theory Study of Structural and Electronic Properties of Group V Transition Metal Carbides

The structural and electronic properties of group V transition metal carbides: VC, NbC and TaC are studied using density functional theory with generalized gradient approximation for the exchange and correlation potentia...

Critical Exponents of Quantum Phase Transition Between U(5) and O(6) Limits of Interacting Boson Model

In this paper, Landau theory for phase transitions is shown to be a useful approach for quantal system such as atomic nucleus. A detailed analysis of critical exponents of ground state quantum phase transition between U(...

Download PDF file
  • EP ID EP595705
  • DOI 10.15415/jnp.2017.51008
  • Views 227
  • Downloads 0

How To Cite

M. C. Grados Luyando, B De Celis-Alonso, E. Moreno-Barbosa, M. I. Martinez Hernandez, J. M. Hernandez Lopez, G. Tejeda Munoz (2017). Characterization Of Structures Of Equivalent Tissue With a Pixel Detector. Journal of Nuclear Physics, Material Sciences, Radiation and Applications, 5(1), 79-89. https://europub.co.uk/articles/-A-595705