Characterization Of Structures Of Equivalent Tissue With a Pixel Detector

Abstract

Research using hybrid pixel detectors in medical physics is on the rise. Timepix detectors have arrays of 256 × 256 pixels with a resolution of 55 µm. Here, and by using Timepix counts instead of Hounsfield units, we present a calibration curve of a Timepix detector analog to those used for CT calibration. Experimentation consisted of the characterization of electron density in 10 different kinds of tissue equivalent samples from a CIRS 062M phantom (lung, 3 kinds of bones, fat, breast, muscle, water and air). Radiation of the detector was performed using an orthodontic X-ray machine at 70 KeV and .06 second of tube current with a purpose-built aluminum collimator. Data acquisition was performed at 1 frame per second and taking 3 frames per phantom. We were able to find a curve whose behavior was similar to others already published. This will lead to the verification of the usage of Timepix for identification of different tissues in an organ.

Authors and Affiliations

M. C. Grados Luyando, B De Celis-Alonso, E. Moreno-Barbosa, M. I. Martinez Hernandez, J. M. Hernandez Lopez, G. Tejeda Munoz

Keywords

Related Articles

Temperature Effects in the Composition of Metal Halide Perovskite thin Films

Metal halide perovskites have shown to be a structure with great promise as an efficient photovoltaic, but at the same time it is affected by instability problems that degrade their performance. Degradation mechanisms va...

Synthesis of MgB4O7:Dy3+ and Thermoluminescent Characteristics at Low Doses of Beta Radiation.

The synthesis and thermoluminescent characteristics of dysprosium-doped MgB4O7 are analyzed. The phosphor at different concentrations (0, 0.1, 0.5, 1, 2 and 4 mol%) of the dopant was prepared by the solution-assisted met...

Radiolysis of Nucleosides: Study of Sedimentary Microenvironment Models for the Protection of Bio-Organic Molecules on Early Earth

Nucleic acid bases and their derivatives are important compounds in biological systems. Many efforts have been made to demonstrate the possible prebiotic origin of these molecules, but the abiotic synthesis of these comp...

The Three-Body Structure of 2n and 2p Halo Nuclei

A three-cluster model developed for ternary fission studies has been applied for the first time to study the three-body structure of 2n and2p halo nuclei. For the experimentally known 2n, 2p halo nuclei, all possible ter...

Radionuclide Determination In Surface Water Samples By Inductively Coupled Plasma With Sector Field Mass Spectrometry (ICP-SFMS)

The determination of naturally occurring radionuclides in the environment by inductively coupled plasma mass spectrometry of high resolution (ICP-SFMS) has gained recognition over the last fifteen years, relative to the...

Download PDF file
  • EP ID EP595705
  • DOI 10.15415/jnp.2017.51008
  • Views 213
  • Downloads 0

How To Cite

M. C. Grados Luyando, B De Celis-Alonso, E. Moreno-Barbosa, M. I. Martinez Hernandez, J. M. Hernandez Lopez, G. Tejeda Munoz (2017). Characterization Of Structures Of Equivalent Tissue With a Pixel Detector. Journal of Nuclear Physics, Material Sciences, Radiation and Applications, 5(1), 79-89. https://europub.co.uk/articles/-A-595705