Clinical evaluation of near-infrared light transillumination (NIRT) as an interproximal caries detection tool in a large sample of patients in a private practice

Journal Title: Journal of Radiology and Imaging - Year 2016, Vol 1, Issue 1

Abstract

Background: A study has been carried out in order to evaluate in vivo the diagnostic performance of near-infrared light transillumination (NIRT) compared to digital radiographic examination (RE) in the detection of class II carious lesions. Methods: A total of 114 patients were included, and 2957 proximal surfaces were considered. Surfaces were imaged by means of NIRT and radiographed with a photostimulable phosphor system. NIRT and radiographic images were observed by two blinded operators. Their diagnoses were compared with those made while visiting the patients, when visual-tactile, radiographic and NIRT data were matched by expert operators to obtain the reference diagnoses. Sensitivity, specificity and inter-observer consistency were calculated. Results: Throughout the visits, 395 caries were detected. When investigating without clinical information and in a blind manner, RE performed significantly better than NIRT regarding sensitivity analysis (0.591 vs. 0.456, p<0.001), and NIRT performed significantly better than RE regarding specificity analysis (0.980 vs 0.933, p<0.001). However, NIRT showed sensitivity similar to RE when only enamel caries were concerned. With regard to the agreement between the two observers, NIRT performed significantly better than RE (0.901 for RE analysis, 0.989 for NIRT analysis, P<0.001). A high probability of false positives for enamel caries (95% from 0.699 to 0.791) was observed in RE. NIRT was very likely to detect and correct the erroneous positive diagnosis of enamel carious lesions obtained using RE (95% CI for probability from 0.938 to 0.979). Conclusions: NIRT should be used in caries diagnosis in combination with radiographic images. In fact, NIRT can help to correct a false positive diagnosis of enamel caries. Furthermore, NIRT could be used to detect caries in patients for whom non-urgent radiographic exposition is contraindicated and to monitor enamel caries in medically treated patients. Finally, thanks to its three-dimensional images, NIRT can aid in detecting small caries when performing minorly invasive restorative procedures.

Authors and Affiliations

Russotto F, Tirone F, Salzano S, Borga FC, Paolino D, Ferraro A, Botasso S

Keywords

Related Articles

Third degree skin burns caused by a MRI conditional electrocardiographic monitoring system

Two unusual cases of third degree skin burns are reported using MRI approved electrocardiographic leads. This is very uncommon as it is most often the electrodes which are the source of heat related issues. Both patients...

The forgotten lymph nodes: Review of the superficial head and neck lymphatic system

In patients with head and neck malignancy, knowledge of the lymphatic pathways relevant to tumor location is important for treatment preparation, both in radiation therapy and in surgery. The lymphatics of the head and n...

CT-guided puncture for direct MR-arthrography of the shoulder: Description of possible techniques

The following report describes the possible techniques of CT-guided puncture for direct magnetic resonance (MR) arthrography of the shoulder. CT-guided puncture can be regarded as an alternative technique to fluoroscopic...

Fetal intracranial neoplasm–not always a teratoma!

Although congenital intracranial tumors are very rare, it is important to know the differential diagnosis and distinguishing features of the different disease processes in order to accurately diagnosis and appropriately...

Point of care ultrasound in cardiac arrest: A case report of PE in PEA arrest

Bedside ultrasound has become an integral part of cardiac arrest resuscitation, enabling the provider to identify potentially reversible conditions in real time. In the setting of pulmonary embolism, bedside ultrasound c...

Download PDF file
  • EP ID EP554099
  • DOI 10.14312/2399-8172.2016-1
  • Views 45
  • Downloads 0

How To Cite

Russotto F, Tirone F, Salzano S, Borga FC, Paolino D, Ferraro A, Botasso S (2016). Clinical evaluation of near-infrared light transillumination (NIRT) as an interproximal caries detection tool in a large sample of patients in a private practice. Journal of Radiology and Imaging, 1(1), 1-5. https://europub.co.uk/articles/-A-554099