Closed Loop Control for Fast Varying Dynamic Load with Transient Free TBSC Compensator

Abstract

Topology for reactive power compensation suitable for dynamic loads in closed loop is presented. The scheme consists of Thyristor Binary Switched Capacitor (TBSC) banks. TBSC is based on a chain of Thyristor Switched Capacitor (TSC) banks arranged in binary sequential manner. A transient free switching of TBSCs is carried out. Proposed topology allows step less reactive power compensation for dynamic loads in very fast responding closed loop. Simulation results show that the proposed scheme can achieve reactive power compensation cycle to cycle basis and the harmonics contents of source are maintained at insignificant levels due to filtering action of TBSC.

Authors and Affiliations

Khushal Shende, D. R. Patil, S. D. Patil, Sumant Lokhande

Keywords

Related Articles

Protection And Restoration in DWDM Metro/Core Application For End to End Recovery

Protection using rings has been the common method of reducing downtime on SONET/SDH based telecommunication networks. With the trend towards IP over DWDM, there is a need for IP based protection and restoration mechanis...

Survey on Privacy Policy Specification System for User Uploaded Images Over Popular Content Sharing Sites

The regular use of social networking websites and application encompasses the collection and retention of personal and very often sensitive information about users. This information needs to remain private and each soci...

Characterization, Treatment and Disposal of Sludge: A Review

Treatment of industrial and domestic effluent is widely studied topic in the environmental engineering. Various techniques used for the wastewater treatment includes biological, physical and chemical treatments. Most co...

Finding Query Facet and Information Retrieval Based on Keyword Search

The path toward finding query facets which are as different social affairs of words Or expressions will be deliver as an issue to clear up and layout the substance secured by a query. It is acknowledged that the basic p...

Quantification and Characterization of Grey Water- A Case Study of Shraddha Nagar, Pusad

Water is the resource that has no alternative. Water is the key element of complex interdependent natural system. Water scarcity has emerged as one of the most pressing problem in the twenty first century. Water scarcit...

Download PDF file
  • EP ID EP22299
  • DOI -
  • Views 243
  • Downloads 4

How To Cite

Khushal Shende, D. R. Patil, S. D. Patil, Sumant Lokhande (2016). Closed Loop Control for Fast Varying Dynamic Load with Transient Free TBSC Compensator. International Journal for Research in Applied Science and Engineering Technology (IJRASET), 4(6), -. https://europub.co.uk/articles/-A-22299