COIL DESIGN WITH LITZE WIRE FOR MAGNETIC PARTICLE SPECTROMETRY

Abstract

The design of an excitation coil for magnetic particles spectrometer (MPS) was described. It was assumed that the spectrometer should measure the spectra of particles of diameter in the range 10-100 nm. To measure the amplitude and phase angle spectra of magnetic nanoparticles it is required to generate sinusoidal alternating spatially homogeneous magnetic field of magnitude of 20 mT. The work volume of the designed spectrometer was 202020 mm allowing measurement of small samples. The estimation of magnetic properties of magnetic nanoparticles is crucial in Magnetic Particles Imaging. In this paper we described the excitation coil design which minimizes power losses on the coil related to heat emission. The resonance circuit operating on 20 kHz frequency was applied. Optimal litze wire configuration was proposed to negate skin and proximity effects. The numeric simulations for the optimal and commercially available suboptimal litze wire configurations were performed. The comparison of the results was shown and discussed.

Authors and Affiliations

Przemysław Wróblewski, Waldemar Smolik

Keywords

Related Articles

ALGORITHM OF TIME STAMPS DISTRIBUTION FOR DATA SYNCHRONIZATION OF VARIOUS MEASUREMENT SYSTEMS

The described in this paper research refer to the finished project which aimed to build the measurement system for phase distribution calculation and two phase flow structure identification based on 3D ECT system. In the...

WITRYNA UCZESTNIKA RYNKU ENERGII ELEKTRYCZNEJ

Aplikacja webowa – Witryna Uczestnika Runku Energii elektrycznej (WURE), powstała jako efekt współpracy autorów nad pracą dyplomową, w 2013 roku.. Celem opracowanej aplikacji, było udostępnienie konsumentom energii elekt...

NADZÓR NAD WYPOSAŻENIEM POMIAROWYM NA PRZYKŁADZIE MIERNIKÓW NATĘŻENIA OŚWIETLENIA

Wyposażenie pomiarowe laboratorium powinno podlegać nadzorowi. Zakres tego nadzoru jestuzależniony od obszaru stosowania przyrządu pomiarowego i powinien obejmować wzorcowanie. Kluczową sprawą jest również prawidłowa eks...

METHODS OF EEG ARTIFACTS ELIMINATION

Registration of electroencephalography signals (EEG) is almost always associated with recording different kinds of artifacts that makesit difficult to read and analyze collected data. These artifacts may be noticeable in...

2D MODELLING OF A SENSOR FOR ELECTRICAL CAPACITANCE TOMOGRAPHY IN ECTSIM TOOLBOX

Electrical capacitance tomography is used to visualize a spatial distribution of dielectrical permittivity of materials placed in a tomographic sensor. An image is reconstructed from measurements of mutual capacitances o...

Download PDF file
  • EP ID EP221809
  • DOI 10.5604/01.3001.0010.4605
  • Views 84
  • Downloads 0

How To Cite

Przemysław Wróblewski, Waldemar Smolik (2017). COIL DESIGN WITH LITZE WIRE FOR MAGNETIC PARTICLE SPECTROMETRY. Informatyka Automatyka Pomiary w Gospodarce i Ochronie Środowiska, 7(1), 150-153. https://europub.co.uk/articles/-A-221809