COLLAPSE ANALYSIS OF STEEL FRAME WITH CONCRETE FILLED STEEL TUBE COLUMNS
Journal Title: International Journal of Civil Engineering and Technology - Year 2019, Vol 10, Issue 3
Abstract
This paper present seismic performance assessment of steel frame consisting of CFST column, according to the procedure provided in FEMA P-58, evaluation of building response and estimating median value of structural response parameters in terms of story drift and story acceleration were carried out. To exactly predict the response, 5-Story and 10-Story buildings are used. In this research paper the response of steel frame with CFST column at failure is obtained by performing a series of non-linear analysis, firstly non-linear static analyses is used to check the yielding and failure roof displacement then incremental dynamic loading is used. IDA is performed with increasing intensities until the collapse is occur then the response of building in terms of storey drift and displacement is obtained. The results obtain show that with vertical irregularities the drift and displacement of building increases and special care should be taken when building built with CFST column is subjected to any vertical irregularities
Authors and Affiliations
ROHAN THAPA, ANKIT MAHAJAN
ANALYSIS OF THE CAUSES OF DAMAGE IN THE BRICKWORK. ELASTIC AND STRENGTH CHARACTERISTICS OF MATERIALS OF MASONRY GRIDS
Brick walls are considered to be among the strongest materials, however, they are subject to destruction. The cause of damage in the brickwork can be both operational and constructive. Even at the stage of construction...
BEHAVIOR ANALYSIS OF THE PERSONAL TAXPAYER ON TAXATION ADMINISTRATION SYSTEM IN THE MERAUKE PRATAMA TAX SERVICE OFFICE
Technological advancements now have an impact on the implementation of tax modernization currently applied by the Directorate General of Taxation in the tax administration process. The purpose of this study is to deter...
ESTABLISHING TRADE UNION IN THE CLIMATE CHANGE OF EMPLOYMENT
There is a fact that trade union have not functioned optimally. A conducive atmosphere is needed to build a trade union. When a conducive atmosphere has been established, then the trade union will be able to implement...
TEMPORAL CHANGE IN VISITOR PERCEPTION AFTER THE THERAPEUTIC FOREST CONSTRUCTION PROJECT - A CASE OF MT. MINJUJISAN, SOUTH KOREA
This study examined the visit characteristics and recognition of visitors on a forest healing program of the Therapeutic Forest over time. Visitors to the Therapeutic Forest of Mt. Minjujisan in South Korea in 2011 and...
EVALUATION OF RECYCLED CONCRETE AGGREGATE AND RICE HUSK ASH WITH POLYVINYL ALCOHOL FIBRE FOR MECHANICAL PROPERTIES OF CONCRETE
The present research work has been done to find the best suitable mix on addition and replacement with some other materials possessing similar physical properties as conventional concrete materials. The materials used...