Comparative Analysis of Probability of Failure Determination Using Weibull Distribution and Generic Failure Frequencies on Heat Exchanger Tube Bundles Based on API 581
Journal Title: International Journal of Marine Engineering Innovation and Research - Year 2018, Vol 2, Issue 3
Abstract
RBI analysis for heat exchanger tube has been explained by API 581. Two types of PoF determination using statistical data is provided to determine the PoF category. Both Weibull parameter and generic failure frequencies are the methods that will be analysis in this present study. PoF determination using Weibull distribution gives the exponential value of PoF in a certain of time. This method only consider failure modes and the failure rate of heat exchanger tube without considering possible active damage mechanisms in the tube. However PoF determination using generic failure frequencies gives more complex consideration. It considers not only failure and possible active damage mechanism, but also the effect of management system facilities of the heat exchanger on the integrity of the plant.
Authors and Affiliations
Dharma Gita Surya Prayoga, Dwi Priyanta, Nurhadi Siswantoro
Flooding Causes Analysis in The Engine Room of KM. Nusantara Akbar
The study analyzes about the cause of the leak in KM Nusantara Akbar’s engine room. However, this research is focus on leakage caused by shaft deflectio From the field data provided by the KNKT, know the cause of the le...
Maintenance Task Allocation And Planning In KT. X Tugboat Using Reliability Centered Maintenance Method
Reliability Centered Maintenance (RCM) as one of the processes that used to decisive action which should be performed to ensure any physical components or a system can work optimally in accordance with the function desir...
Development of Power Management System for Electric Power Generation in Tanker Ship Based on Simulation
Power management system (PMS) for electric power generation in ship, in the case of tanker ship, is the system that has function to control and to monitor all generators in ship as the main electricity supplier for all e...
The Study of the Application of Hybrid Propulsion System on OPV with Controllable Pitch Propellers
As a patrol ship, the offshore patrol vessel (OPV) 80 m has an operational profile consisting several conditions: loitering (10 knots), patrol (18 knots), and interception (22 knots). Applying diesel mechanical propulsio...
Vibration Spectrum Analysis for Indicating Damage on Turbine and Steam Generator Amurang Unit 1
Maintenance on machines is a mandatory asset management activity to maintain asset reliability in order to reduce losses due to failure. 89% of defects have random failure mode, the proper maintenance method is predictiv...