Comparative Evaluation of Accuracy of Pulse Oximeters and Factors Affecting Their Performance in a Tertiary Intensive Care Unit
Journal Title: Journal of Clinical and Diagnostic Research - Year 2017, Vol 11, Issue 6
Abstract
Introduction: Pulse oximetry is a widely used tool, unfortunately there is a paucity of data investigating its accuracy in Intensive Care Units (ICU) and if they are able to meet mandated FDA criteria as claimed by them in critically ill patients. Aim: To assess bias, precision and accuracy of pulse oximeters used in ICU and factors affecting them. Materials and Methods: A prospective cohort study, including 129 patients admitted to the ICU of a tertiary referral centre. Pulse oximetry and blood gas were done simultaneously. Pulse oximetry was done using two pulse oximetres: Nonin and Philips. All physiological variables like haemoglobin, lactate, use of vasopressors and blood pressure were recorded. Bland Altman curves were constructed to determine bias and limits of agreement. Effect of physiological variables on bias and difference between performance characteristics of bias was determined using SPSS. Results: Pulse oximetry overestimated arterial oxygen saturation (SaO2 ) by 1.44%. There was negative correlation between bias and SaO2 (r=-0.32) and positive correlation with lactate (r=0.16). The Philips pulse oximeter had significant higher bias and variability than Nonin pulse oximeter. (2.49±2.99 versus 0.46±1.68, mean difference = 1.98, 95% C.I. = 1.53 – 2.43, p-value <0.001). Conclusion: Pulse oximetry overestimates SaO2 . Bias tends to increase with rising lactate and hypoxia. There is heterogeneity in performance of various pulse oximetry devices in ICU
Authors and Affiliations
Anupam Kumar Singh, Malvinder Singh Sahi, Bablesh Mahawar, Sajjan Rajpurohit
Mixed Mucinous Male Breast Carcinoma: A Rare Histological Variant of a Rare Disease
Male breast carcinoma is rare neoplasm, accounting for <1% of all diagnosed breast malignancy. Histologically, most often it is infiltrating ductal carcinoma and rarely mucinous carcinoma. A 73-year-old male presented wi...
A Rare Case of Genital Malformation with Omphalocele, Exstrophy of Bladder, Imperforate Anus and Spinal Defect Complex-Autopsy Findings
Omphalocele, Exstrophy of cloaca, Imperforate anus and Spinal defects (OEIS) is a severe manifestation of exstrophy-epispadias sequence with a combination of defects including OEIS. It results from improper closure of an...
Reliability and Validity of the Indian (Telugu) Version of the Shoulder Pain and Disability Index
ABSTRACT Introduction: The Shoulder Pain and Disability Index (SPADI) is one of the most commonly used shoulder specific self report questionnaires that is available to evaluate patients with shoulder pathology but it ha...
Comparison of Refractive Error Measurements between KR-1W Wavefront Analyser and KR-8800 Automatic Refractometer in School Children
ABSTRACT Introduction: A number of methods and instruments, such as retinoscopy, Hartmann-Shack sensor, ray tracing method and rotary prism technology, are available for assessing refractive status in clinic. The literat...
Effect of Crown Angulation of Maxillary Incisor on Effective Arch Perimeter
Introduction: It has been postulated that crown angulation and inclination has potential space implication within the arch. With the insight of space implication of the axial relations of teeth, cases of genuine tooth si...