Comparative evaluation of dynamic torsional resistance of the nickel titanium instruments manufactured with different technologies

Journal Title: International Journal of Applied Dental Sciences - Year 2017, Vol 3, Issue 2

Abstract

Aims: To compare and evaluate the dynamic torsional resistance of nickel titanium instruments manufactured with different technologies. Methods: 60 new rotary NiTi instruments were selected and divided into 4 subgroups of 15 files each: Protaper (Dentsply Maillefer, Ballaignes, Switzerland) based on coventional SE wire technology, Twisted file (Sybron Endo, Orange, CA) based on R-phase technology, Hyflex CM (Coltene Whaledent, Cuyahoga Falls, Ohio) based on Controlled Memory and Protaper Next (Dentsply Maillefer, Ballaignes, Switzerland) based on M-wire technology. A customised stainless steel apparatus consisting of block with a cubical hole (5mm×5mm×5mm) and assembly for holding and adjusting the handpiece was fabricated. 5 mm of the tip of each file was embedded in this composite resin block, and a uniform torsional stress at a speed 300 rpm and 1.8 N.cm torque were applied repetitively by an endodontic motor (X-Smart; Dentsply Maillefer, Ballaigues, Switzerland) with auto-stop mode until the file subjected to torsional failure. The number of load applications leading to fracture were recorded. All fractured surfaces were examined under the SEM for determining the mode of fracture. Tabulated data was statistically analysed using mean and standard deviation. ANOVA and Unpaired ‘t’ test were applied to find the significant difference between the different groups. Results: Protaper files showed significantly higher dynamic torsional Resistance followed by Protaper Next (45.2), Hyflex CM (2.733) and lowest values were obtained for Twisted file but there was no statistical difference between Hyflex CM and Twisted file groups. SEM examination revealed a typical pattern of torsional fracture for all the groups characterized by circular abrasion marks and skewed dimples near the center of rotation Conclusions: Protaper files showed comparatively and significantly higher dynamic torsional resistance than all other file systems followed by Protaper Next, Hyflex CM and Twisted files. Hyflex CM and Twisted files exhibited the same dynamic resistance to torsion.

Authors and Affiliations

Vaikunth Aggarwal, Dr. Vipin Arora, Sachin Gupta

Keywords

Related Articles

MRI characteristics of disc displacement of temporomandibular disorders and its correlation with clinical findings in symptomatic and asymptomatic subjects

Objectives: Pain caused by temporomandibular disorders originates from either muscular or articular conditions, or both. Distinguishing the precise source of the pain is a significant diagnostic challenge to clinicians,...

Fracture resistance of maxillary premolars with mod cavities restored with Zirconomer: An in vitro comparative study

Aim: To test the fracture resistance of maxillary premolars with MOD cavities restored with a new Zirconia reinforced Glass Ionomer Cement (Zirconomer) and to compare it with other conventional posterior restorative mate...

Use of innovative suction device to improve the retention in denture wearer patients - A pilot study

Introduction: Denture technology is constantly moving forward and providing denture wearers with better and better options for denture comfort and fit. There are some products and systems in the market that will raise th...

Assessment of the force decay and the influence of pH levels on three different brands of latex and non-latex orthodontic elastics: An in vitro study

Elastics are one of the most versatile material available to the orthodontist. Its an invaluable tool of the orthodontist armamentarium. The effects of salivary pH levels on viscoelastic force relaxation of nonlatex inte...

The Miracle Twig -Miswak

Chewing sticks are being used as oral hygiene aid since 3500 BC. There are more than 180 plant species from which chewing sticks are being prepared, among which Miswak (tooth cleaning stick) which is harvested from Salvo...

Download PDF file
  • EP ID EP529033
  • DOI -
  • Views 70
  • Downloads 0

How To Cite

Vaikunth Aggarwal, Dr. Vipin Arora, Sachin Gupta (2017). Comparative evaluation of dynamic torsional resistance of the nickel titanium instruments manufactured with different technologies. International Journal of Applied Dental Sciences, 3(2), 202-205. https://europub.co.uk/articles/-A-529033