Comparative Evaluation of Shear Bond Strength of Prefabricated Composite Veneer Bonded to PolyEther-Ether Ketone Framework using two Different Bonding Systems: an Invitro Study

Journal Title: IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) - Year 2018, Vol 17, Issue 4

Abstract

Objectives: The aim of this study was to evaluate and compare the shear bond strength of prefabricated composite veneer bonded to polyether-etherketone(PEEK) implant prosthetic framework using two different bonding systems. Materials and methods: 40 pre-fabricated composite veneers (novo.lign A -bredent GmbH,Germany) for central incisors were selected and cemented to a PEEKframework using two different bonding systems–Group A using visio.link primer-combo.lign luting composite resin (bredent GmbH,Germany) and Group B using GC Composite Primer(GC,Europe) and LuxaCore Z bonding resin(DMG, Germany).After ageing the specimens by storage in distilled water at room temperature for 24 hours, shear bond strength of composite veneer bonding was tested on universal testing machiene. Results: Shear bond strength valueswere more for Group A (5.95MPa) than Group B (3.19MPa) which was statistically significant. SEM analysis showed that mixed type of bond failure were more commonly observed in thebonding systems. Conclusion: Shear bond strength of visio.link-combo.lign bonding system was more than GC composite primer-LuxaCore Z bonding system. The type of bond failure was mostly mixed failure in both the groups along with cohesive failure within the veneer suggesting that the veneering system was not appropriate for the PEEK frameworks

Authors and Affiliations

Reshma Premkumar, Vinni T K, Pramod Kumar AV, Gilza K Vasunni, Sampath K

Keywords

.

Related Articles

“Operative outcome of Trochanteric femoral nailing for intertrochanteric fractures of femur in adults”

Context: Intertrochanteric fractures account for half of proximal femur fractures.This extra capsular fracture occurs in cancellous bone with abundant blood supply. As a result non union and osteonecrosis are not a major...

Survey on Power Transmission Behaviour of Microgrid

The power transmission network, as a standard between utilization centers and power generation, includes a limited capability in addition to its own security concerns. Deregulation in electricity markets took place when...

Variations in Branching Pattern of Superior Mesenteric ArteryA Cadaveric Study

Objective:The aim of this study was to detect and describe the existence and incidence of anatomical variations of the superior mesenteric artery by using dissection method.Materials and methods: 40 cadavers dissected, a...

Study of Prevalence of Tuberculosis among Patients Attending Chest OPD of A Rural Medical College in North Maharashtra.

Introduction: Major challenges to control TB in India include Strengthening of primary health-care infrastructure in rural areas of country. Medical College & hospital in rural area is definite hope in improving diagnosi...

Evaluation of Non Febrile Seizure Disorder on MRI with Correlation with Seizure Type and EEG Records in Children.

Objectives: The aim of this retrospective study was to investigate the spectrum of abnormality on MRI, to correlate MRI findings with the seizure type and EEG findings wherever available in children presenting with non f...

Download PDF file
  • EP ID EP370587
  • DOI 10.9790/0853-1704061522.
  • Views 61
  • Downloads 0

How To Cite

Reshma Premkumar, Vinni T K, Pramod Kumar AV, Gilza K Vasunni, Sampath K (2018). Comparative Evaluation of Shear Bond Strength of Prefabricated Composite Veneer Bonded to PolyEther-Ether Ketone Framework using two Different Bonding Systems: an Invitro Study. IOSR Journal of Dental and Medical Sciences (IOSR-JDMS), 17(4), 15-22. https://europub.co.uk/articles/-A-370587