Comparative evaluation of the effect of Light Emitting Diode (LED) and Quartz Tungsten Halogen (QTH) light curing units on color stability of Filtek Z350 XT

Journal Title: Caspian Journal of Dental Research - Year 2014, Vol 3, Issue 1

Abstract

Introduction: Discoloration of the resin-based composites is a common problem in restorative dentistry. There are many factors associatedwith the discoloration of dental materials in the oral environment. The purpose of this study was to evaluate the color changes in a nano-composite cured with a quartz-tungsten-halogen (QTH) and light emitting diode (LED) unit. Methods: 80 disk-shaped specimens were prepared using Filtek Z350 XT. The specimenswere cured with two LED units (Valo and BluephaseC5) andQTH )Astralis7(with two different energy density (400 & 750 mW/Cm²). The color of the materials was measured before and after immersingin tea and artificial saliva.Color change value (ΔE) were calculated and analyzed by 2-way ANOVA and Tukey’s test. Results:In artificial saliva group,the compositescured with Astralis7 and BluephaseC5 showed significantly more color stability. In tea group, the composites cured with BluephaseC5 significantly had the least color change. Conclusions:The type of light curing unitdoes not affectthe color stability. Exposure time and interaction between light source and photoinitiator content in composite may be the most important factors affecting color stability.

Authors and Affiliations

Behnaz Esmaeili, Shaghayegh Razavi, Mahdie Pakdaman, Ali Bijani, Hoda Amiri

Keywords

Related Articles

Effect of composite shade, curing time and mode on temperature rise of silorane and methacrylate- based composite resins

Introduction: The present study was performed to evaluate the effects of light-curing modes and shades of methacrylate and silorane-based composite resins on temperature rise during polymerization of composite resins. Ma...

Comparative evaluation of the frequency of myofibroblasts between oral and cutaneous squamous cell carcinomas

Introduction: Differentiation of fibroblasts to myofibroblasts is an initial and very important event in tumor genesis. Myofibroblasts produce proteinases that stimulate invasion in cancers. Due to the more malignant pot...

Clinical and denture-related characteristics in patients with epulis fissuratum: a retrospective 58 case series

Introduction: Epulis fissuratum is one of the important denture-related mucosal lesions that occurs around the borders of an ill-fitting denture. The purpose of this study was to analyze the cases of epulis fissuratum ad...

Accuracy of vertical bitewing radiography in determination of root length of maxillary primary molars

Introduction: Considering the good geometry and possibility of simultaneous observation of the roots of the maxillary and mandibular molars in vertical bitewing radiography, the present study was conducted to evaluate th...

Analgesic effects of gabapentin and ibuprofen on the pain in post therapy of root canal; a randomized double-blind clinical trial

Introduction: Inhibiting the pain which affects both the patients and dentists is an important factor during treating dental patients. The aim of this study was to assess the analgesic effect of two medications ibuprofen...

Download PDF file
  • EP ID EP178966
  • DOI -
  • Views 118
  • Downloads 0

How To Cite

Behnaz Esmaeili, Shaghayegh Razavi, Mahdie Pakdaman, Ali Bijani, Hoda Amiri (2014). Comparative evaluation of the effect of Light Emitting Diode (LED) and Quartz Tungsten Halogen (QTH) light curing units on color stability of Filtek Z350 XT. Caspian Journal of Dental Research, 3(1), 41-46. https://europub.co.uk/articles/-A-178966