Comparative Investigation of Pollution Accumulation and Natural Cleaning for Different HV Insulators
Journal Title: Engineering, Technology & Applied Science Research - Year 2015, Vol 5, Issue 2
Abstract
High Voltage insulators are scattered throughout any HV network and a single insulator fault may cause an excessive outage. Reliability is a key issue for electric power systems and fault-free performance of insulators greatly reflects on the reliability of the system. Environmental influence is rather important for the optimum selection of outdoor insulators and, therefore, field measurements provide valuable information. Utilities perform such measurements in order to decide upon the location/route of new HV installations (substations, lines etc) and also to optimize the selection, maintenance and replacement of already installed insulators. A rather interesting case in Greek territory is the island of Crete, due to the coastal development of the network and the local weather conditions. The Greek utility has employed a variety of remedies to cope with the pollution problem. Following the positive feedback after the installation on certain tower in the past, a large project to replace all ceramic insulators with new polymer ones of hydrophobic surface is now in progress. Polymer coatings have also been extensively applied on substations and also on certain areas/towers of the transmission network in the past. In order to investigate the pollution accumulation and the impact of natural washing on different insulator types, a series of periodical ESDD and NSDD pollution measurements were conducted in HEDNO’s TALOS High Voltage Test Station for a 3-months period. Multiple measurements were performed on each insulator every month in order to collect additional data. Five different insulators were selected based on the types historically used in the Cretan Network. Along with the standard glass disc profile, two strings of glass fog profile (the one coated with RTV) and two long-rod composite insulators of different shed profile and material were used. Results are presented and discussed in this paper.
Authors and Affiliations
M. Dimitropoulou, D. Pylarinos, K. Siderakis, E. Thalassinakis, M. Danika
Ductility Evaluation of Steel Structures with Reduced Beam Sections and Post-Tensioned Cables Using the Finite Element Method
Given the importance of structure strengthening, this research introduces a particular type of steel structure in which the reduced beam section and post-tensioned cables were used for creating centralized property and p...
State-Space Modeling and Performance Analysis of Variable-Speed Wind Turbine Based on a Model Predictive Control Approach
Advancements in wind energy technologies have led wind turbines from fixed speed to variable speed operation. This paper introduces an innovative version of a variable-speed wind turbine based on a model predictive contr...
Comparison Between Conditions of Major Roads Within and Outside the Port of Durban
Over the past years road traffic has increased at the Port of Durban. Due to the lack of maintenance, this has resulted in road deterioration. Roads are considered as the most important transport mode at the Port of Durb...
Fuzzy Predictive Force Control (FPFC) for Speed Sensorless Control of Single-side Linear Induction Motor
In this paper a model fuzzy predictive force control (FPFC) for the speed sensorless control of a single-side linear induction motor (SLIM) is proposed. The main purpose of of predictive control is minimizing the differe...
Impact of Inadequate Experience and Skill on the Construction Sector in KwaZulu-Natal, South Africa
Civil engineering contractors encounter serious challenges in order to sustain their businesses, especially in a weak economic climate. A certain level of construction experience, expertise and training are required to...