Comparative study between proximal femoral nail and dynamic hip screw with trochanteric stabilizing Plate (TSP) in unstable intertrochantric femur fractures
Journal Title: International Journal of Orthopaedics Sciences - Year 2018, Vol 4, Issue 4
Abstract
Background: Unstable fractures accounts for approximately 50 to 60% of all intertrochanteric fractures. Failure rates of (DHS) dynamic hip screw for unstable fracture patterns are as high as 50%. Proximal femoral nail is technically more demanding surgery and also associated with complications like implant failure, femoral shaft fracture, improper reduction, screw cut-out and non-union. This study was done to compare the results of using Trochanteric stabilization plate in addition to dynamic hip screw versus proximal femoral nail which is considered as a better implant for unstable fractures. Materials and Methods: A prospective study was conducted comparing outcomes of proximal femoral nailing versus trochanteric stabilization plate with dynamic hip screw for 44 patients with unstable intertrochanteric fractures (22 each). Modified Harris Hip scoring system and Parker mobility score was used for evaluation. Results: In our study, Average time of union in all 22 patients of PFN group was about 12 weeks while average time of union in all 22 patients of DHS with TSP group was about 14 weeks. The Harris hip score was 85.45 in DHS with TSP group while it was 84.72 in the PFN group (p=0.846). The Parker mobility score was 7.81 in the DHS with TSP group while it was 7.95 in the PFN group (p=0.728). Conclusions: Use of TSP with DHS can give good results in unstable IT fractures. Addition of TSP to DHS gives good lateral wall buttress which prevent excessive medialisation of shaft and gives comparable result to PFN.
Authors and Affiliations
Dr. Parameswar Rao G, Dr. Siddaram N Patil
Online validity and accuracy of references within drug promotion materials in orthopaedic out-patient department
Background - In the era of evidence based medicine, correct and relevant information should accompany any broadcast of pharmaceutical related knowledge. A substandard piece of information has potential for negative impac...
Clinical & radiological analysis of results of primary hemiarthroplasty using cemented bipolar modular prosthesis in fracture neck of femur
Single assembly total hip prosthesis, which sought to provide a completely mobile head elements and an additional head surface to allow movement within the acetabulum. Thus he aimed to create a compound system providing...
Management of pathological femoral fracture secondary to Ewing sarcoma in pregnancy: A case report
Ewing's sarcoma is an ultra-orphan disease (2/1,000,000/year) which requires a multimodal therapy approach in high-volume centers. Treatment consists of pre-operative therapy followed by surgery and post-operative combin...
Role of locking dynamic hip screw in management of inter-trochanteric fractures of femur in elderly patients
Introduction: Dynamic Hip screw is the implant of choice for most inter-trochanteric fractures of the femur. But, its most common mode of failure is for the lag screw to cut out of the femoral head, the second is for the...
Correlation of clinical, radiological and arthroscopic findings of meniscal and anterior cruciate ligament injuries of knee
Background: Orthopaedic surgeons commonly see soft tissue injuries of the knee including meniscal and ligament injuries. In the past diagnosis of these injuries was based on accurate clinical examination alone as plain r...