COMPARATIVE STUDY OF ACCURACY OF BIOMETRIC FORMULAS OBTAINED BY APPLANATION A-SCAN BIOMETRY.

Journal Title: International Journal of Advanced Research (IJAR) - Year 2019, Vol 7, Issue 2

Abstract

Aim of the study: To evaluate and compare the accuracy of different intra ocular lens (IOL) power calculation formulas for predicting post operative refraction in eyes of different axial lengths using applanation A scan biometry Methods: In prospective study, conducted in GREH, Visakhapatnam with 50 eyes.Axial lengths were calculated by applanation A-scan biometry. All eyes were divided into three groups according to AL: short (<22.0 mm), average (22.0?25.0 mm), and long (>25.0 mm) eyes. IOL power calculation was done using the five Formulas SRKII, SRK/T, HOLLADAY 1, HOFFERQ, and BINKHORST 2. All patients were subjected to SICS with PCIOL implantation under local anaesthetia.The implanted power of IOL was based on SRK II formula. Final refraction was measured 6 weeks postoperatively.Post-operative spherical equivalent (SE) was calculated and compared with predicted refractive error using each biometric formula. Results: All formulas had a significantly lower MAE in comparison with BINKHORST II formula. SRK II and SRK/T had lowest MAE (0.58?0.44) for all eyes. SRK II had the lowest MAE for average (0.54?0.40) and short (0.67?0.54)eyes.SRK/T had the lowest MAE (0.63?0.48) for long eyes. BINKHORST II formula had highest MAE for all (0.69?0.48) and average (0.68?0.46) eyes. HOFFER Q formula had highest MAE (0.76?0.65) for short eyes and SRK II had highest MAE (0.89?0.64) for long eyes Conclusion:SRK II and SRK/T are accurate formulas for average eyes.SRK II and HOLLADAY I are best formula of choice in short eyes.SRK/Tis accurate IOL formula for long eyes followed by HOLLADAY I and HOFFER Q .

Authors and Affiliations

V a n p kumari oruganti, k. Venkateswarlu, kaavyahanuraj kolalapudi, p. shyam sundar.

Keywords

Related Articles

WHAT ARE THE CHANGES IN THE USE OF IS/LM MODEL EVER SINCE ITS INCEPTION?

International Journal of Advanced Research (IJAR)

THE HIGHER EDUCATIONAL INSTITUTIONS IN ARUNACHAL PRADESH: AN ANALYTICAL STUDY.

Arunachal Pradesh is the late starter in formal education. The history of higher education in the state started with the establishment of the J.N. College, Pasighat in 1964. Now the state has more than fifty numbers of g...

TOPICAL CO-DELIVERY OF INDOMETHACIN AND NIGELLA SATIVA L. ESSENTIAL OIL IN POLY--CAPROLACTONE NANOPARTICLES: IN VIVO STUDY OF ANTI-INFLAMMATORY ACTIVITY.

Indomethacin is a potent, nonselective Non-steroidal Anti-inflammatory Drug (NSAID) but its low water-solubility precludes its use as topical dosage form. As with other NSAIDs, the systemic delivery is associated with hi...

THE EFFECTS OF WORKPLACE HARASSMENT ON CO-WORKER RELATIONSHIP AND WORK ENGAGEMENT: A DEVELOPING COUNTRY PERSPECTIVE.

This study aims to examine the effects of workplace harassment on the relationship amongst co-workers and their work engagement. It is one of the few studies to explain the effects of workplace harassment in a developing...

PLACENTA PREVIA ACCRETA RISK FACTORS AND PRENATAL DIAGNOSIS BY COLOR.

Background: The incidence of placenta accreta has increased dramatically over the last three decades, in concern with the increase in the cesarean delivery rate. Optimal management requires accurate prenatal diagnosis. O...

Download PDF file
  • EP ID EP483448
  • DOI 10.21474/IJAR01/8495
  • Views 66
  • Downloads 0

How To Cite

V a n p kumari oruganti, k. Venkateswarlu, kaavyahanuraj kolalapudi, p. shyam sundar. (2019). COMPARATIVE STUDY OF ACCURACY OF BIOMETRIC FORMULAS OBTAINED BY APPLANATION A-SCAN BIOMETRY.. International Journal of Advanced Research (IJAR), 7(2), 362-365. https://europub.co.uk/articles/-A-483448