COMPARATIVE STUDY OF HEMOGLOBIN ESTIMATION BY DIFFERENT METHODS
Journal Title: GJRA-Global Journal For Research Analysis - Year 2019, Vol 8, Issue 1
Abstract
Background: Hemoglobin (Hb) estimation is one of the most frequently ordered investigations. Estimation of exact levels is important to stratify the grade of anemia and subsequently direct the necessary treatment. Conventionally, Hb has been estimated using colorimetric method, which is time tested and recommended by the WHO. Now-a-days, the automated method is also becoming a popular method in many hospitals. However, there are not many studies assessing the accuracy of the automated method over the gold standard. Materials and methods: We retrospectively analyzed hemoglobin values in 180 adult patient-samples (18 per batch in 10 batches). Hemolyzed samples were excluded from the study. Blood samples were drawn in vials having K3 EDTA anticoagulants. After a proper mixing, hemoglobin was estimated by automated Sysmex XS-800i. Parallel estimation for Hb content was done manually by spectrophotometer 4010. Results: Patients ranged from ages 20 to 40 years (M:F=102:78). The lowest value recorded by Sysmex XS-800i was 5.8 while the highest value recorded was 18.6 gm%. The mean hemoglobin concentration on Sysmex XS-800i was 12.89. The lowest, highest and mean values recorded by the cyanmethemoglobin method on photometer were 5, 18 and 13.49 gm% respectively. This showed a mean difference of 0.597 and with signicant p-value of <0.001. Conclusion: The lowest values of Hb were similar in both the methods but the mean as well as the highest values differed signicantly. Our study found an accuracy of 95.57% with the 5 part analyzer when compared to the gold standard colorimetric method.
Authors and Affiliations
Dr. Priya Singh, Prof. (Dr. ) Sharique Ahmad, Dr. Sudarshana Gogoi, Prof. (Dr. ) A N Srivastava
CONSTRUCTION AND STANDARDIZATION OF A TOOL TO MEASURE LEARNING INTEREST IN MATHEMATICS AMONG HIGH SCHOOL STUDENTS
The present Study is an attempt to construct and standardize a tool for measuring the Learning interest in Mathematics of individual students in different dimensions which include interest in learning Mathematics, teache...
Ketofol Anaesthesia for Short Gynaecological and Obstetric Procedures in ASA 1 & 2 Patients
Propofol and ketamine are intravenous anaesthetic agents. They are used for induction of Anaesthesia as their effect lasts for 20 minutes. Ketamine causes sympathetic stimulation where as propofol causes cardiac depressi...
TURMERIC CULTIVATION AND EMPLOYMENT GENERATION OF WOMEN THROUGH CLUSTER BASED APPROACH IN ASSAM
In this paper an attempt was made to study the Turmeric Cultivation and Employment Generation of Women through Cluster based approach in Assam. The study was conducted in Balijana block of Goalpara district of Assam cove...
A STUDY OF PROPHYLACTIC PHENYLEPHRINE INFUSION FOR PREVENTING HYPOTENSION DURING SPINAL ANAESTHESIA FOR CESAREAN SECTION:
BACKGROUND: Hypotension after spinal anaesthesia for Caesarean section still remains a common complication. Various methods have been recommended for prevention and treatment of this problem. However, despite crystalloid...
Evaluation of Antioxidant Properties of A Pigment Molecule Isolated from Radioresistant Bacterial Strain Inm-2
Moleculesoffers radioresistantto an organism can be exploited as radioprotective drug for the human uses. Bacterial pigment assumed to be one of these molecules as itpossesses antioxidant properties.Present investigation...