Comparative Study of Various Seismic Analysis Methods for Rc Structure
Journal Title: International Journal of engineering Research and Applications - Year 2017, Vol 7, Issue 6
Abstract
A large number of RC frame buildings have been built in India in recent years. Huge number of similarly designed and constructed buildings exist in the various towns and cities situated in moderate to severe seismic zones of the country. Analysis and design of such buildings for static forces is a routine affair these days because of availability of affordable computers and specialized programs which can be used for the analysis. On the other hand, dynamic analysis is a time consuming process and requires additional input related to mass of the structure, and an understanding of structural dynamics for interpretation of analytical results. Reinforced Concrete (RC) frame buildings are most common type of constructions in urban India, which are subjected to several types of forces during their lifetime, such as static forces due to dead and live loads and dynamic forces due to earthquake. To ensure safety against seismic forces of multi-storied building hence, there is need to study of seismic analysis to design earthquake resistance structures. In the present study a multi-storied framed structure is selected, And Linear seismic analysis is done for the building by static method (Equivalent Static Method) and dynamic method (Response Spectrum Method & Time history Method) using ETAB2016 as per the IS-1893-2002-Part-1. As a result, the response of structure has been obtained for considered building models, based on each methods of analysis, and then the results are compared with each other.
Authors and Affiliations
Wahane Rasika Murlidhar, Phuke Rahul M.
Assessment of Water Quality Index of the Kolong River of Nagaon District of Assam, India
The objective of the study is to analyze the Water Quality Index (WQI) and analysis of variations of Water Quality Index parameters along the Kolong River,Nagaon, Assam, after the breaching of Hatimura dyke in 2017. WQI...
Detection Of Epileptic Seizure From EEG Signal Using Wavelet Transform And Artificial Neural Network
Epilepsy is the fourth most common neurological problem in which brain activities becomes abnormal, causing seizure or unusual behavior and sometimes loss of awareness. An electroencephalogram (EEG) signal is used to det...
Comparison of Mechanical Properties of Bare and Stellite-21 Coated Aisi 316l, Sprayed By D-Gun Process
Present paper describes the mechanical properties of Stellite-21 coated AISI- 316LStainless steel. Specimens were coated using Detonation Gun thermal spray process,with different coating thicknesses of Stellite-21 rangin...
An Optimal Design of UP-DOWN Counter as SAR Logic Based ADC using CMOS 45nm Technology
In this paper an analog to digital converter architecture is introduced. The proposed design is based on Up-Down counter approach SAR type ADC. This design offers less design complexity which leads to low power consumpti...
The Effect of Using a Modified A/C System on the Cooling System Temperature of an Internal Combustion Engine
This study investigates the effect of using A/C refrigerant to reduce the temperature of the coolant in a vehicle cooling system. An increase in coolant temperature due to harsh working conditions increases fuel consumpt...