COMPARATIVE STUDY OF VERTICAL MARGINAL FIT ON IMPLANT ABUTMENT USING METAL CERAMIC CROWNS, FULL CONTOUR ZIRCONIA CROWNS (CAD/ CAM) AND VENEERED ZIRCONIA CROWNS (CAD/ CAM) (AN IN VITRO STUDY)
Journal Title: World Journal of Pharmaceutical Research - Year 2017, Vol 6, Issue 12
Abstract
Background: Marginal fitness is an important factor in success and longevity of implant – retained restoration.) Objective: To evaluate and compare vertical marginal fit among three materials used in construction crowns in the dental implant (metal- ceramic- full contour zirconia- veneered zirconia crowns. Material and method:- Four implant abutment on maxillary cast with first premolar and first molar (right & left )on both side receive thirty crowns on were divided into three group :- Group A:-10 samples were constructed with metal ceramic crowns used lost wax technique. Group B:-10 samples were constructed with full-contour zirconia crowns used (Imes –Icore) CAD-CAM system. Group C:-10 samples were constructed with veneered zirconia crowns used (Imes –Icore) CAD-CAM system. Vertical marginal gaps were measured at four points on each tooth surface. Sixteen points per tooth sample were measured using a digital microscope at a magnification of (230X). The marginal discrepancy found by use the mean of this sixteen points the Comparison of significance among the different groups using (Kruskal- Wallis H) test showed a statistically highly significant differences (p < 0.000). Furthermore, comparison of significance between each pair of groups using Paired-Samples, (Mann- Whitney U) showed statistically highly significant differences (p < 0.000). Results: The results of this study revealed that the least marginal gaps were, recorded at full contour zirconiaa crowns using (Imes –Icore) CAD-CAM system (39,239 -+26,575 um) and highest marginal gap were recorded at metal ceramic crowns using lost wax technique (92,513- +32,466 um) and veneered zirconia crowns were between of them (68,433-+40, 346 um). In conclusion, full contour zirconia crowns constructed with CAD-CAM system provided butter marginal fit and showed smaller marginal gap compare with metal ceramic crowns and veneered zirconia crowns.
Authors and Affiliations
Dr. Sabiha Mahdi Kanaan
PATTERN OF ANALGESICS USE IN ORTHOPEDIC WARDS OF KING SAUD MEDICAL CITY, RIYADH, SAUDI ARABIA
Background: Over the past 2 decades, KSA has recorded 86,000 deaths, and 611,000 injuries in road traffic accidents but information on the drug utilization pattern in the orthopedics inpatients in Kingdom of Saudi Arabia...
EVALUATION OF ANTIBIOTIC RESISTANCE CASES IN ARIS DISEASE: POTENTIAL TEST AND COMPARATIVE TEST OF LEVOLOXACIN ANTIBIOTICS USED IN TASIKMALAYA CITY HEALTH CENTER
Objective: Acute respiratory infection (ARIs) is an acute respiratory infection that attacks the throat, nose and lungs caused by viruses, bacteria, rickettes. Antibiotics is one way to overcome the disease ARIs. Ineffec...
WHITE BLOOD CELLS AND PLATELETS AS PREDICTIVE PARAMETERS IN DENGUE FEVER
Dengue fever is an epidemical viral infection which causes the death of dozens in some of the Yemeni governorates recently. The aim of this study was to consider whether dengue infection can be suspected based on haemato...
“SEERAKA CHOORANAM” A SIDDHA FORMULATION FOR IRATHTHAK KOTHIPPU NOAI (HYPERTENSION)
Iraththak kothippu noai (Hypertension) is one of dangerous non communicable diseases in the world. National survey on health of Sri Lankans finds 18 percent of population suffers a chronic illness. Among the cases report...
INFECTION PREVENTION AND CONTROL: GENERAL PRINCIPLES AND ROLE OF MICROBIOLOGY LABORATORY
The healthcare-associated infections HAIs are international health problem and its major cause of death worldwide with wide range complications among healthcare workers, patients, and visitors, And these complications ar...