Comparative Study of Westergren Method and Automated ESR Analyser (Microsed-10)

Journal Title: Journal of Medical Science And clinical Research - Year 2016, Vol 4, Issue 10

Abstract

Background & Objectives: The erythrocyte sedimentation rate (ESR) is still widely used in clinical practice as an indicator of inflammation, infection, trauma, or malignant disease and several billion tests are being performed in clinical laboratories throughout the world. Present study is to compare the ESR done by MicroSED 10, an automated ESR analyser and by the Westergren method in, Individual with normal range ESR, Individual with anaemia, Individual with tuberculosis, Paediatric patients, Orthopaedic patients, Individual with metastasis, Male individual and Female individual. Method: Total 500 Blood samples are taken in sodium citrate vacutee. First ESR is measured by westergren method. Then same sample is run in the Automated ESR analyser Microsed-10. Results: R value of this study is 0.44. So the present study is significant for using automated ESR method instead of gold standard westergren method in patient with individual with normal range(0.43), anaemia(0.49), paediatric patients(0.45), individual with metastasis(0.97), individual with tuberculosis (0.37), male individual (0.44) and female individual(0.44) have significant R value so in these cases automated ESR Analyser can be used for gold standard westergren method. Orthopaedic patient (0.24) have low R value, so automated ESR cannot be used for gold standard westergren method.

Authors and Affiliations

Drashti N. Shukla

Keywords

Related Articles

Study on Prevalence and Patterns of Dyslipidemia among Kodavas

Cardiovascular diseases are increasing and dyslipidemia is an important cause. Therefore, it becomes very essential to study these risk factors in the Kodava community, which has been ignored and seem to be predisposed t...

Recurrent Dermatofibrosarcoma Protuberans on Anterior Abdominal Wall A Case Report and Review of Literature

Dermatofibrosarcoma Protuberans (DFSP) is an uncommon, slow growing, locally aggressive cutaneous neoplasm. Incidence of DFSP is 0.8 to 4 cases per 1 million per year. Dermatofibrosarcoma protuberans accounts for less th...

Carcinoma Cervix in Pregnancy Presenting as Antepartum Haemorrhage: A Case Report

Cervical Cancer is the most common genital malignancy associated with pregnancy. It usually presents in the 1st trimester and at an early stage. Presentation can be variable ranging from pain abdomen to bleeding per vagi...

A Study of Hypertension and Its Risk Factors among Rural Population in the Field Practice Area of Mahatma Gandhi Medical College and Hospital, Jaipur

Background: Hypertension is an important global health issue of the 21st century, which has developed together with rapid economic growth, urbanization, aging population, changing life style and other unhealthy behaviour...

Effect of Intravenous Dexmedetomidine on the Action of Spinal Bupivacaine in Comparision with Intravenous Midazolam

Background: The present study was designed to evaluate the effect of intravenous dexmedetomidine on the action of spinal bupivacaine in comparision with intravenous midazolam. Materials and methods: Study was done for a...

Download PDF file
  • EP ID EP214637
  • DOI -
  • Views 112
  • Downloads 0

How To Cite

Drashti N. Shukla (2016). Comparative Study of Westergren Method and Automated ESR Analyser (Microsed-10). Journal of Medical Science And clinical Research, 4(10), 13325-13329. https://europub.co.uk/articles/-A-214637