Comparative study on fixed versus adjustable-length loop device for femoral fixation of graft in anterior cruciate ligament reconstruction
Journal Title: International Journal of Orthopaedics Sciences - Year 2018, Vol 4, Issue 1
Abstract
Aims and Objectives: Cortical suspension devices have been widely used in ACL reconstruction for femoral side graft fixation. Fixed-length and adjustable-length loop devices are two common suspensory loop devices that are used in ACL reconstruction. They both have their own biomechanical pros and cons. The purpose of this study is to determine the difference in functional outcome of anatomical single bundle ACL reconstruction using fixed length versus adjustable length loop in femoral fixation of quadrupled hamstring graft. Material and methods: It is a longitudinal prospective study conducted in Bone and Joint Centre, Kokilaben Dhirbhai Ambani Hospital (KDAH), Mumbai from Jan 2014 to June 2016. There were 60 patients enrolled in the study. The first 30 patients were treated with Arthroscopic ACL reconstruction in the first 30 patients were done with quadrupled hamstring graft from ipsilateral limb fixed with Endobutton on femoral side and bio-absorbable intrafix tibial screw, similarly in subsequent 30 patients ACL reconstruction were done with quadrupled hamstring graft from ipsilateral limb fixed with Tightrope on femoral side and bio-absorbable intrafix tibial screw. Their clinical and functional status were assessed pre-operatively on the day prior to surgery and the last follow up at one following the surgery with Tegner-Lysholm Score and 2000 IKDC scores. Results: The average Tegner- Lysolm score before surgery in Endobutton group was 56.63±6.7 and post op score at last follow up was 93.97±4.1 and for Tightrope group it was 56.5±7.1 and 94.7±3.7 respectively. The average 2000 IKDC score before surgery in Endobutton group was 46.16±6.1and post-op score at last follow up was 82.52±4.2 and for Tightrope group it was 46.57±6.5 and 83.98±4.1 respectively. Two sample student t-test was conducted to compare the mean of post-operative Tegner-Lysolm score and 2000 IKDC for each group it showed P value for Tegner-Lysolm score to be 0.75 and that for 2000 IKDC score to be 0.7, which not statistically significant to reject the null hypothesis. Discussion and conclusion: Cortical suspension devices for femoral tunnel graft fixation are very efficient devices whether Fixed-length or adjustable length. Fixed-length and adjustable loop cortical suspension devices are equally effective in femoral fixation of graft in ACL reconstruction.
Authors and Affiliations
Pokharel B, Bhalodia M, Raut A, Gajjar SM
Comparative study of intramedullary interlocking nailing and minimally invasive percutaneous plate osteosynthesis (MIPO) in extra articular distal tibial fracture
Introduction: Tibia is one of the most commonly fractured long bone of the body. Distal tibia fractures are primarily located within a square based on the width of the distal tibia. Treatment of distal tibia fracture is...
A Prospective study on the functional outcome following arthroscopic ACL reconstruction with the femoral interference screw placed through the PT (Patellar Tendon) portal and the AM (Antero-Medial) portal
The knee joint is the most commonly injured of all joints and the anterior cruciate ligament is the most commonly injured ligament. Arthroscopic reconstruction of torn ACL has become the gold standard in treating ACL tea...
Outcome of pediatric shaft femur (6 to 12 years) treated with intramedulary nailing
Fracture of shaft femur is a common injury in young boys and girls. Many controversy present about treating them between conservative and operative. In our study,we have evaluated outcome of fracture shaft femur in pedia...
Management of diaphyseal fractures of both bones of forearm by internal fixation using locking compression plate and screws
Background and objective: The fractures of both bones forearm are one of the commonest fractures found and can be treated by different methods. The accepted management for fractures of both bones forearm is open reductio...
The role of entry point and correct reduction in post-operative outcome of intertrochanteric femur fractures treated by short and long proximal femoral nails
Introduction: This study was performed in the department of orthopaedics, VIMSAR, Burla between July 2015 and June 2017 for evaluation of outcome of the surgical treatment of patients with intertrochanteric fracture trea...