Comparative Thermal Analysis of Aluminum Alloy and Mild Steel for the Development of the Cascade of a Transformer

Journal Title: Scholars Journal of Engineering and Technology - Year 2017, Vol 5, Issue 11

Abstract

This work investigates thermal evaluation between two materials-aluminum alloy and mild steel for the development and fabrication of the cascade of a transformer. The ingenuity behind this comparative analysis on thermal performance of these two materials is saddled on the reoccurrence of transformers failures in the recent times especially in the tropics. A fair normal ambient temperature is favourable because it acts as heat sink but a scenario where the ambient temperature and the transformer temperatures are too close, it become dangerous to the operating conditions of this electrical device. A fast heat dissipation medium is needed to optimize cooling for the coils of the transformer. A model of cascaded transformer is developed using Creo Element and built with Ansys Work Bench to analyze aluminiun alloy and carbon steel AISI 1095. Properties of these material were carefully selected using a material reasource base software- Granta 2011©.The steady and transient thermal analysis for carbon steel AISI 1095 with maximum -temperature distribution of 96.325oC ,and total heat flux 1.9463×〖10〗^6 W⁄(m C)on a steady analysis and maximum temperature of 114.62C and toatal heat flux of 1.7172×〖10〗^6 W⁄m C and cast aluminum alloy with maximum -temperature distribution of 96.344oC ,and total heat flux 8.9827×〖10〗^6 W⁄(m C)on a steady analysis and maximum temperature of 114.65C and toatal heat flux of 6.793×〖10〗^6 W⁄m C . Comparatively, aluminum alloy will perform better than carbon steel AISI 1095.

Authors and Affiliations

Asha Saturday, Felix Omeanenemeh Patricks, Ogbe Blessing Omokwudu, Erukpe Aluhumile Peter, Ageh A. Terna

Keywords

Related Articles

Efficiency of Coagulation Process and Constructed Wetland for the Treatment of Municipal Solid Waste Landfill Leachate

Landfill leachate is a fluid that is from the external water which enter into the landfill solid waste, dissolve and rinse the dissolved materials including organic matter. It usually has high content of organic matter,...

Verification of the Primary Stability of Bone-Implant Non Manifold Assembly (Prosthetic Joint) using Hertzian Contact Mechanics Model

The problem with hip replacement technology is a challenging one and no addition to that effort is a wasted venture. The aim of this work considering stainless steel SS316L as the implant material was to investigate the...

Problem of Transport Network Analysis for Identifying Bottlenecks

Abstract:The analysis was done and an algorithm was developed for calculating a route in the urban transport network. Based on the input data, this algorithm determines the capability to pass the given flow between two p...

Optimization of injection parameters for air foam profile control in low permeability oil field

Abstract: In view of the high water cut, effect of strong anisotropy, low water drive spread coefficient and injected water channeling of M block in A oil field, some research on the technology of M block air foam profil...

A Method of Finding Solutions to the Cubic equation x3+px2+qx+r=0

A method of finding real and complex solutions to the cubic equation is illustrated through solving quartic equation. Keywords: Cubic equation, real roots, complex roots, quartic equation 2010 Mathematics Subject Class...

Download PDF file
  • EP ID EP386642
  • DOI -
  • Views 99
  • Downloads 0

How To Cite

Asha Saturday, Felix Omeanenemeh Patricks, Ogbe Blessing Omokwudu, Erukpe Aluhumile Peter, Ageh A. Terna (2017). Comparative Thermal Analysis of Aluminum Alloy and Mild Steel for the Development of the Cascade of a Transformer. Scholars Journal of Engineering and Technology, 5(11), 602-613. https://europub.co.uk/articles/-A-386642