Comparing Uterine Electromyography & Tocodynamometer to Intrauterine Pressure Catheter for Monitoring Labor

Journal Title: Journal of Woman’s Reproductive Health - Year 2016, Vol 1, Issue 3

Abstract

Objective The tocodynamometer (TOCO) has poor sensitivity and specificity in monitoring uterine contractions, especially in obese patients. The intrauterine pressure catheter (IUPC) can be used to monitor adequacy of contractions, but only after amniotomy. Transabdominal uterine electromyography (EMG) and the TOCO were compared to the gold standard IUPC for monitoring uterine contractions. Methods Forty term pregnant women in labor with ruptured membranes were consented for this study. The root mean square (RMS) plot from EMG signals was compared to IUPC and TOCO recordings for 20 to 40 minutes. A comparison between the total contraction number, frequency, and the difference in contraction peak time was made using Student-t test or ANOVA (P<0.05 was significant). Results There was no significant difference in the contraction number and frequency when comparing the RMS, TOCO, and IUPC. The paper tracings had a greater standard deviation (8.57) than the digitally saved data (3.93). The mean peak time difference between TOCO and IUPC was 0.74 seconds (P=0.78; SD 5.2). For RMS vs. IUPC peaks, the mean peak difference between was 0.13 seconds (P=0.95; SD 3.93). Conclusions Uterine electrical activity measured with transabdominal uterine EMG may be used to monitor labor in patients as an alternative to the TOCO and the IUPC.

Authors and Affiliations

Sangeeta Jain, Sanmaan S. Basraon, Antonio F. Saad

Keywords

Related Articles

Placenta Previa with History of Previous Caesarean Delivery – an Obstetrician's Nightmare

Background: The nature of placenta previa can be unpredictable and harsh on the mother and baby. These complications are often unpredictable, unpreventable and often leave the labour ward team in a dilemma. This Obstetr...

Advances in Sexual and Reproductive Rights of Adolescents in Brazil

The paper presents the incorporation of sexual and reproductive rights in the legislation of Brazil, considering the influence of the discussions that involved the United Nations conferences of Cairo and Beijing. Are des...

Ordeals of Sexually Violated Women and Access to Comprehensive Healthcare: A Case Study of Victims of Sexual Violence in North Kivu, Eastern Congo

Background: The impact of sexual violence in any community is extremely devastating and women in the Eastern part of the Congo are no exception. Sexual violence not only affects the health of women, but it impacts their...

Horizontal Inequities in the uptake of Hospital Delivery and the Role of Social Determinants in China

Objectives: To measure the horizontal inequity in the uptake of hospital delivery and quantify the contribution of various social determinants of health (SDH) to such inequity in China from 1993-2008 Methods: With four...

Download PDF file
  • EP ID EP322759
  • DOI 10.14302/issn.2381-862X.jwrh-15-771
  • Views 126
  • Downloads 0

How To Cite

Sangeeta Jain, Sanmaan S. Basraon, Antonio F. Saad (2016). Comparing Uterine Electromyography & Tocodynamometer to Intrauterine Pressure Catheter for Monitoring Labor. Journal of Woman’s Reproductive Health, 1(3), 22-30. https://europub.co.uk/articles/-A-322759