Comparison and Agreement between Venous and Arterial Blood Gas Values for pH, pCO2, pO2, Bicarbonate and Oxygen Saturation in Patients with Acute Respiratory Illnesses

Journal Title: Journal of Medical Science And clinical Research - Year 2017, Vol 5, Issue 3

Abstract

Arterial blood gas (ABG) analysis is routinely performed for sick patients but is fraught with complications, is painful, and is technically demanding. As there is a huge requirement of performing ABG analysis, an alternative to the arterial puncture would be quite helpful in this setting, and the current study was aimed to determine the extent of correlation of arterial and venous blood gas (VBG) analysis with a view to identifying whether the venous samples can be used as an alternative to arterial values in clinical management of patients presenting with various acute respiratory illness. This prospective observational study was conducted on 90 patients who presented with acute respiratory illness in in-patient Department of Medicine and Pulmonology, Mata Chanan Devi Hospital, after applying specific inclusion & exclusion criteria. Pregnant ladies, patients having age less than 20 years and those who were having respiratory symptoms due to non-respiratory causes were excluded from this study. Arterial sample was drawn via an arterial puncture into a heparinized syringe in all patients and at the same time, venous blood was also taken, without application of tourniquet via antecubital vein into another heparinized syringe. Venous and arterial blood samples were taken within 5-minutes of each other and in addition to this, the measurement of oxygen saturation (SpO2) was obtained from finger pulse oximeter. In order to access the agreement between values of two samples, the paired t-test and Pearson correlation coefficient was used. The mean age of the patient in the present study was 62.4 ± 14.75 years and gender distribution was 54 males and 36 females out of total 90 patients. After statistical evaluation, the present study shows minimal difference and good correlation between arterial and venous samples for the values of pH, bicarbonates, pCO2 ( r > 0.9 ). Although the correlation of pO2 measurement was fair ( r = 0.615 ) , but there was good correlation between values of finger pulse oximeter and arterial oxygen saturation( r > 0.9 ). Thus, venous blood may be a useful alternative to arterial blood during blood gas analysis in the management of patients with acute respiratory illnesses. However, further large scale studies are needed to accurately assess whether VBG analysis can always replace ABG analysis

Authors and Affiliations

Shobhit Shah

Keywords

Related Articles

Transversus Abdominis Plane Block Versus Wound Infiltration of Local Anesthesia For Post Operative Analgesia

Background: Since the concept of day care surgeries are getting more popular, surgeons and anesthesiologists are trying their best to provide adequate post operative analgesia. Infiltration of surgical wound with local a...

Demography, Clinico-Pathological Features and Outcome of Extrapulmonay Tuberculosis: 2 Years Prospective Study

Tuberculosis (TB) is an infectious disease that primarily affects lungs followed by other organs. Extrapulmonary TB can present with non-specific symptoms such as unintentional weight loss (more than 1.5 kg in a month),...

Choroid Plexus Carcinoma of Third Ventricle – A Case Report

Choroid plexus carcinomas are extremely rare and rapidly growing intra ventricular tumors which are more frequently seen in young children. Choroid plexus tumors commonly involve lateral ventricles and fourth ventricle a...

Study of Dermatophytic Infections and Isolates in a Rural Tertiary Care Hospital

Background: Dermaptophytes are dimorphic fungi which cause infections on skin, hair and nail. Dermatophytoses is an important health problem in both developed and developing countries. Aim: To study about the dematophyti...

HIV Threat: A Study among Blood Donors

Background: The Human Immunodeficiency Virus (HIV) has been able to threaten the human population all over the world. Among the various routes of spread of HIV, blood transfusion is a major route. So, an integrated strat...

Download PDF file
  • EP ID EP279057
  • DOI -
  • Views 92
  • Downloads 0

How To Cite

Shobhit Shah (2017). Comparison and Agreement between Venous and Arterial Blood Gas Values for pH, pCO2, pO2, Bicarbonate and Oxygen Saturation in Patients with Acute Respiratory Illnesses. Journal of Medical Science And clinical Research, 5(3), 19069-19077. https://europub.co.uk/articles/-A-279057