Comparison Between Thermo Luminescence Dosimeter and Planning System Dose Calculation in The Brain and Spinal Cord Tumour
Journal Title: JOURNAL OF ADVANCES IN PHYSICS - Year 2019, Vol 16, Issue 1
Abstract
Radiotherapy of Spinal cord and brain tumor requires High care due to considerable changes in the white matter of the brain, which consequently lead to a reduction of patient learning and mental skills. It is considered a very critical tumor due to high sensitivity of gross volume location and normal tissues surrounding it, including eye, heart, plate thyroid, and testis. XiO planning systems, TLD dosimeter found in Mansoura university oncology department, CMS XIO USA TPS were compared using electron and photon beams with different energies at a different site in target volume and organs at risk. We conclude that regular calibration of planning systems and direct measurement of the dose delivered to main target and organs at risk should be done to avoid the difference between XiO planning systems and direct measurement by TLd.
Authors and Affiliations
Ehab A Hegazy
CHARACTERISTICS OF PARTICLES PRODUCED IN HADRON-NUCLEUS COLLISIONS
A detailed study on mean multiplicities of secondary charged particles is presented. The average number of grey, black and heavy particles are found to be independent of energy in proton-nucleus interactions whereas for...
Influence of Au on Ge Crystallization and Its Thermoelectric Properties in a Au-induced Ge Crystallization Technique
Poly-crystalline Ge (pc-Ge) thin films were prepared on a SiO2/Si substrate using Au-induced crystallization (GIC) of amorphous Ge (a-Ge) with an annealing temperature around the eutectic point of Au-Ge alloy system (361...
Complex Impedance Measurements on the Steady State Behaviors of a 10-cell PEFC Stack
Experimental studies on the behavior of a Polymer Electrolyte Fuel Cell (PEFC) stack were conducted by performing complex impedance measurements. Initially, the steady state characteristics of a 10-cell stack were measur...
The Magnetocaloric Properties of Gd5Si4 Alloy Prepared by the New Method
We report on a new method for preparation the magnetocaloric alloy Gd5Si4. By mechanical alloying under argonatmosphere and then melting sample by arc furnace, we produced the Gd5Si4 alloy. The structure and magnetotherm...
PHYSICAL AND OPTICAL PROPERTIES OF THE FILMS ?i2Te3-Bi2Se3
Results of researches show, that film p-n the structures received by a method of discrete thermal evaporation in a uniform work cycle, are suitable for use in low-voltage devices. As a result of work are received p...