Comparison of Accuracy of various Impedance Based Fault Location Algorithms on Power Transmission Line

Journal Title: International Journal of Science and Research (IJSR) - Year 2015, Vol 4, Issue 3

Abstract

Transmission line protection is important issue in power engineering because 85-87% of power system faults are occurring in transmission lines. This paper presents three developed algorithms: Takagi’s method, Ericsson method, Fault sequence component of current method. MATLAB/ Simulink software was used to implement these algorithms. The accuracy of fault location on power transmission line are compared for these three method by varying various parameters like fault type, fault resistance, fault location and fault inception angle, on a given power system model. The simulation results demonstrate the validity of the suitable fault location method in 400KV transmission line.

Authors and Affiliations

Keywords

Related Articles

Brokering Strategy in Network and Resource Performance with Multi Node Proxy Server

Brokering Strategy in Network and Resource Performance with Multi Node Proxy Server

Integrity Attestation and Auto-correction of Services for SaaS Clouds

SaaS systems helps the Application Service Provider-s (ASP-s) to convey their service to the users by making use of cloud computing infrastructure. But because of the partake nature of SaaS clouds, they are often exposed...

Corporate Sustainability Reporting in Emerging Economies - A Review and Future Direction

Over the last few decades public awareness of the environmental, social and economic impacts of business has increased at a dramatic rate. In parallel with this, the development of communications technology has both empo...

Security Enhanced Communication Scheme with Compression on Encrypted Cipher Block

"The process of exchanging ideas or information between two persons or stations or devices is termed as communication. The information security has become one of the most significant problem in data communication. The in...

Remotely Counsel and Governing WLAN through Wi-Fi Enabled Android Device

This paper demonstrates how the WIRELESS LAN monitoring and controlling is done through the android phone when administrator is not present at a network place. It is integrated software that allows administrator to remot...

Download PDF file
  • EP ID EP357524
  • DOI -
  • Views 45
  • Downloads 0

How To Cite

(2015). Comparison of Accuracy of various Impedance Based Fault Location Algorithms on Power Transmission Line. International Journal of Science and Research (IJSR), 4(3), -. https://europub.co.uk/articles/-A-357524