Comparison of Airtraq optical laryngoscope and Storz video laryngoscope in a cadaver model

Journal Title: World Journal of Emergency Medicine - Year 2011, Vol 2, Issue 3

Abstract

BACKGROUND: Airway management in the emergency department is a critical intervention that requires both standard techniques and rescue techniques to ensure a high rate of success. Recently, video laryngoscope (VL) systems have become increasingly common in many large urban EDs, but these systems may exceed the budgets of smaller rural EDs and EMS services and the Airtraq optical laryngoscope (OL) may provide an effective, low-cost alternative. We hypothesized that laryngeal view and time to endothracheal tube placement for OL and VL intubations would not be significantly different. METHODS: This was a prospective, crossover trial. Setting: University-based emergency medicine residency program procedure laboratory utilizing lightly embalmed cadavers. Subjects: PGY1-3 emergency medicine residents. The study subjects performed timed endotracheal intubations alternately using the OL and VL. The subjects then rated the Cormack-Lehane laryngeal view for each device. Statistical analysis: Mean time to intubation and the mean laryngeal view score were calculated with 95% confidence intervals and statistical significance was determined by Student's t test. RESULTS: Fourteen subjects completed the study. The average laryngeal view achieved with the OL vs. the VL was not significantly different, with Cormack-Lehane grade of 1.14 vs. 1.07, respectively. Time to endotracheal intubation, however, was significantly different (P<0.001) with the average time to intubation for the OL 25.49 seconds (95% CI: 17.95-33.03) and the VL 13.41 seconds (10.27-16.55). CONCLUSION: The Airtraq OL and the Storz VL yielded similar laryngeal views in the lightly embalmed cadaver model. Time to endotracheal tube placement, however, was less for the VL.

Authors and Affiliations

Keywords

Related Articles

Therapeutic benefits of mild hypothermia in patients successfully resuscitated from cardiac arrest: A meta-analysis

BACKGROUND: Good neurological outcome after cardiac arrest (CA) is hard to achieve for clinicians. Experimental and clinical evidence suggests that therapeutic mild hypothermia is beneficial. This study aimed to assess t...

Evaluation of factors affecting psychological morbidity in emergency medicine practitioners

BACKGROUND: Assessing and evaluating mental health status can provide educational planners valuable information to predict the quality of physicians' performance at work. These data can help physicians to practice in the...

Emergency department use among patients from residential aged care facilities under a Hospital in the Nursing Home scheme in public hospitals in Queensland Australia

BACKGROUND: Hospital emergency department (ED) use by patients from residential aged care facilities (RACFs) is not always appropriate, and this calls for interventions to avoid some unnecessary uses. This study aims to...

Upregulated expression of S100A8 in mice brain after focal cerebral ischemia reperfusion

BACKGROUND: Recent studies have showed that S100A8 has been implicated in the pathobiology of inflammatory disorders, and that cerebral ischemia reperfusion (I/R) rapidly activates inflammation responses via Toll-like re...

Expression of heat shock protein 70 in lung tissues of acute paraquat poisoned rats and intervention of ulinastatin

BACKGROUND: Paraquat (PQ) is an effective herbicide and is widely used in agricultural production, but PQ poisoning is frequently seen in humans with the lung as the target organ. Clinically pulmonary pathological change...

Download PDF file
  • EP ID EP473657
  • DOI -
  • Views 63
  • Downloads 0

How To Cite

(2011). Comparison of Airtraq optical laryngoscope and Storz video laryngoscope in a cadaver model. World Journal of Emergency Medicine, 2(3), 176-178. https://europub.co.uk/articles/-A-473657