COMPARISON OF AUTOMATED AND MERCURY BLOOD PRESSURE MEASUREMENT AMONG PREGNANT WOMEN IN RURAL HEALTHCARE SETTINGS
Journal Title: Journal of Evidence Based Medicine and Healthcare - Year 2017, Vol 4, Issue 36
Abstract
BACKGROUND Various kinds of error can arise during the process of blood pressure measurement and it is more with Mercury Sphygmomanometers (MM). Its comparability with the use of Automated Blood Pressure Measurement Devices (AD) is unequivocal. So, the present study was taken up to compare the blood pressure measurement using automated and mercury sphygmomanometer among the pregnant women in primary healthcare settings of Hassan district. The aim of the study is to compare clinical blood pressure measurement using automated and mercury sphygmomanometers among pregnant women in primary healthcare settings. MATERIALS AND METHODS A cross-sectional study was conducted in two primary health centres of Hassan district between February 2016 to August 2016. Blood pressure was recorded in 357 pregnant women using both mercury and automated sphygmomanometers (Omron HEM-8721). Two readings were taken in sitting position in a nondominant arm with one minute gap using both devices separately. The mean of two recordings recorded with both the devices were considered as the blood pressure of that mother. There was a 2-minute gap between automatic and manual BP readings. All measurements were obtained under similar conditions except for the two different BP recording techniques used. The ethical clearance has been taken from Institutional Ethical Committee. Data was analysed by using SPSS 18. RESULTS The mean age of the participants was 22.56±3.29. The mean of systolic blood pressure using the MM and AD were 106.35±10.07 and 106.16±11.30 respectively and mean of diastolic blood pressure were 66.65±9.39 and 66.53±9.42, respectively. Systolic BP was >130 mmHg for 17 manual and 14 automated measurements. Diastolic BP was ≥90 mmHg for 13 manual and 11 automated BP readings. Through scatter plot-it was found highly correlated between systolic and diastolic measurement using two different types of instruments. Also, for reliability between variables, Cronbach’s alpha value found was 0.917 and 95%, CI; 0.89-0.93, which is highly significant. CONCLUSION Digital blood pressure equipment is equally efficient and comparable to conventional ones in all aspects for wider usage in different setups.
Authors and Affiliations
Sundar Muniswamy, Uma Sakkara Kenchanna
DIETARY RISK FACTORS OF METABOLIC SYNDROME IN DIBRUGARH DISTRICT OF ASSAM
BACKGROUND As India is considered as the diabetic capital of the world, a huge burden of undiagnosed Metabolic Syndrome (MetS) is a possibility. Early intervention can be planned if MetS can be detected early along with...
ASSESSMENT OF DEMOGRAPHIC PROFILE OF PATIENTS ADMITTED WITH A DIAGNOSIS OF ALLEGED SELF-HARM AT A TEACHING HOSPITAL IN HINDI HEARTLAND
BACKGROUND At any point of time, we can observe several cases of alleged self-harm in our medical wards. Although most of the studies look at nature and types of poison and its management & prognosis, there is a lack of...
A PROSPECTIVE AUTOPSY STUDY OF CHEST INJURIES BY BLUNT TRAUMA
Trauma is one of the leading preventable causes of death in developing countries, and is a major health and social problem. Trauma affects generally the young people, and accounts for loss of more years of life, than los...
RADIODIAGNOSIS OF PLEURAL LESIONS WITH USG AND CT SCAN
BACKGROUND Ultrasound is easy available, less expensive study. It differentiates pleural effusion, consolidation and masses. CT scores in diagnosing early pleural lesions and helps in localising lesions differentiating b...
A CASE OF CONGENITAL LOBAR EMPHYSEMA: CHALLENGES IN DIAGNOSIS AND IN ANAESTHETIC MANAGEMENT
Congenital lobar emphysema (CLE) is a rare clinical entity presenting as acute respiratory distress in infants. Its diagnosis is difficult as clinically and radio logically it mimics pneumonia or pneumothorax. Its early...