Comparison of axial length measurement on swept-source optical biometry and optical coherence interferometry

Journal Title: Eye Science (Yanke Xuebao) - Year 2020, Vol 35, Issue 2

Abstract

[Objective:] To compare the detection rates and consistency of axial length (AL) measured by a new swept-source optical coherence tomography biometry (OA-2000) and an optical coherence interferometer (IOLMaster 500) in cataract patients, and to evaluate the application value of OA-2000 in the axial length measurement of cataract patients. [Methods:] In this retrospective study, 561 cataract patients (954 eyes) admitted to Guangzhou Aier Eye Hospital from March to August in 2018 were recruited. AL measurement before cataract surgery was performed by OA-2000 and IOLMaster 500 respectively. The detection rates, correlation and the consistency were analyzed based on chi-square test, Pearson correlation coefficient, intraclass correlation coefficient (ICC) and Bland-Altman plot, respectively. [Results:] The success rates of AL measurement by OA-2000 and IOLMaster 500 was 95.4% and 64.7%, respectively. The detection rate with two instruments significantly differed (P<0.05). Pearson correlation analysis showed a high correlation of AL measurement values between OA-2000 and IOLMaster 500 (r=1, P<0.05), and the scatter plots of AL measurement values were distributed in a straight line. Bland-Altman analysis revealed a high consistency in the AL measurement values between two instruments. [Conclusion:] The consistency and correlation AL measurement are high between OA-2000 and IOLMaster 500. In the AL measurement of cataract patients, the detection rate of OA-2000 is higher than that of IOLMaster 500, which deserves higher application value in clinical practice.

Authors and Affiliations

Mansha HE, Yun CHEN, Zheming WU, Ruihong JU, Shulun XIAO, Weitao ZHENG

Keywords

Related Articles

Medial-inferior wall orbital decompression combined with fat decompression in the treatment of moderate-to-severe thyroid associated ophthalmopathy

[Objective:] To observe the clinical efficacy of medial-inferior wall orbital decompression combined with fat decompression in the treatment of moderate-to-severe thyroid associated ophthalmopathy (TAO). [Methods:] A ret...

Research progress in the treatment of neurotrophic keratopathy with corneal neurotization

Neurotrophic keratopathy is a disease related to degenerative changes in corneal nerves, resulting in impaired sensory and nutritive functions of corneal nerves. This leads to corneal epithelial defects, corneal ulcers,...

Research on abnormal movement behavior caused by damage to visual function of glaucoma and prospect of rehabilitation treatment

Glaucoma is a blinding eye disease that cannot be ignored worldwide. Its onset is insidious, visual impairment is progressing rapidly, and the late prognosis is not ideal. Long-term untreated glaucoma patients show progr...

A case analysis of non-organic visual loss misdiagnosed as optic neuritis in children

Non-organic vision loss is also known as psychogenic or functional vision loss. In addition to vision loss, it can also be accompanied by visual field defects, mostly caused by conversion disorders induced by mental and...

Effect of peripheral patching on binocular dominance in adult visual cortex

[Objective:] To study the effect of short-term peripheral patching on binocular dominance in adult visual cortex. [Methods:] Monocular short-term peripheral patching was performed on each eye (24 eyes) of 12 normal adult...

Download PDF file
  • EP ID EP763400
  • DOI 10.3978/j.issn.1000-4432.2020.04.01
  • Views 21
  • Downloads 0

How To Cite

Mansha HE, Yun CHEN, Zheming WU, Ruihong JU, Shulun XIAO, Weitao ZHENG (2020). Comparison of axial length measurement on swept-source optical biometry and optical coherence interferometry. Eye Science (Yanke Xuebao), 35(2), -. https://europub.co.uk/articles/-A-763400