Comparison of Bishop score and cervical length measurement through transvaginal ultrasound as prediction against labor induction

Journal Title: Asian Pacific Journal of Reproduction - Year 2018, Vol 7, Issue 6

Abstract

Objective: To compare the Bishop score and cervical length measured by transvaginal ultrasound concerned with prediction over the success of labor induction. Methods: This cross-sectional observational analytical study was conducted from May 2017 to October 2017 at several teaching hospitals of Obstetrics and Gynecology Department, Faculty of Medicine Hasanuddin University of Makassar, India. There were 110 samples of pregnant women undergoing labor induction process including 79 samples of successful induction and 31 samples of induction failure. The data analysis used Pearson Chi-square test and multivariate logistic regression to see the effect of Bishop score and measurement of cervical length with successful induction of labor. Results: Number of samples with successful labor induction with Bishop score <3 was 25 (31.6%) and Bishop score ≥ 3 was 54 (68.4%), with rate ratio=3.714 and P=0.000. With measurement of cervical length (cut-off point 2.98 cm), number of samples with successful labor induction with cervical length≤ 2.98 cm was 12 (15.2%) and cervical length >2.98 cm was 67 (84.8%), with rate ratio=3.124 and P=0.000. Multivahate analysis of logistic regression was found to be more influential in the predicted success of labor induction (P=0.014 with Bishop score <3, odds ratio=1.000 and Bishop score ≥ 3, odds ratio=3.779. Conclusions: Bishop score is better in predicting the success of labor induction compared to the measurement of cervical length through transvaginal ultrasound.

Authors and Affiliations

Finianty Raynelda, Efendi Lukas, Sriwijaya Qadar, Maisuri T Chalid

Keywords

Related Articles

Molecular interaction of zp3 to zp3r reveals a cross-species fertilization mechanism

Objective: To evaluate the role of ZP3R in the species-specific fertilization mechanism. Methods: ZP3/ZP3R protein sequences of Mus musculus, Rattus norvegicus, and Cavia porcellus were downloaded from UNIPROT. Percentag...

Genetic polymorphism and natural fertility in women

Objective: To investigate the cooperative interaction among five genetic systems (phosphoglucomutase locus 1, adenosine deaminase locus 1, acid phosphatase locus 1, adenylate kinase locus 1, and haptoglobin) concerning t...

Prediction of protein structure of novel protein (116 kDa) from human sperm membrane

Objective: To predict the protein similarity, biological function and structure of 116 kDa protein that was isolated from human sperm membrane of acrosome by using in silico. Methods: Predictions for 116 kDa protein simi...

Heritability and variance components estimates for growth traits in Saudi Ardi goat and Damascus goat and their crosses

Objective: To study the genetic and non-genetic factors and their interactions affecting growth rate and body weights at birth, weaning and at 6 months of age in Saudi Ardi, Damascus goats and their crosses. Methods: Cro...

Orexins and male reproduction

Orexins (or hypocretins) are hypothalamic neuropeptides with a multitude of physiological functions. They occur in two known forms, namely, orexin A and orexin B with a common precursor, preproorexin. The orexin receptor...

Download PDF file
  • EP ID EP417470
  • DOI 10.4103/2305-0500.246348
  • Views 222
  • Downloads 0

How To Cite

Finianty Raynelda, Efendi Lukas, Sriwijaya Qadar, Maisuri T Chalid (2018). Comparison of Bishop score and cervical length measurement through transvaginal ultrasound as prediction against labor induction. Asian Pacific Journal of Reproduction, 7(6), 280-284. https://europub.co.uk/articles/-A-417470