Comparison of epileptic seizure prediction performance for different EEG derivation schemes

Abstract

Introduction. The influence of EEG derivation scheme on performance of epileptic seizure prediction is considered in the paper. Comparison of epileptic seizure prediction performance for different EEG derivation schemes is conducted. Database of EEG recordings from 20 patients (between 1 and 25 years old) suffering epilepsy was used. Correlation coefficients between channels of signal extracted with different combination of window and preictal lengths were used as features. Support vector machine was used to classify EEG data into interictal and preictal classes. Epileptic seizures prediction performance was evaluated using area under the ROC-curve for two types of derivation schemes: monopolar scheme with reference electrode on ipsilateral ear and scheme with averaged reference. Conclusions. It was found that there is a difference in epileptic seizures prediction performance for different schemes and patients. For subgroup of patients (9 of 20) usage of scheme with reference electrode in ipsilateral ear shows higher performance for window length between 2 and 10 seconds and in entire range of preictal lengths. Scheme with averaged reference shows higher performance when window length is in the range between 90 and 300 seconds.

Authors and Affiliations

O. Panichev, A. Popov, V. Kharytonov

Keywords

Related Articles

Voice signal segmentation using wavelet transforms

This article provides a voice channel segmentation algorithm using the multiresolution analysis and wavelet transform, which features both within the stationary sites significant role for the analysis of language play si...

Digital Signal Extraction by Means of Nonlinear Stochastic Filtration

The results of noise immunity analysis for digital communication systems using methods of nonlinear filtering are given. Nonlinear filtration is based on stochastic resonance effect. The stochastic resonance is given to...

Segmentation of anatomical heart structures in Ensite Verismo software for radiofrequency ablation of arrhythmogenic tissues

Review of the problem. The relevance of the research is the need of a high-quality imaging of the left atrium anatomy for the effectiveness of radiofraquency ablation of arrhythmogenic tissue of the myocardium in real ti...

Increased noise signal processing in incoherent radar systems

Introduction. The work is devoted to the method of increasing coherence and noise immunity pulse radar systems with incoherent sources probing signals. Problem. Incongruities between a resolution and a range of pulsed ra...

Regulated four tact transistor inductance

Marketability function of inductance is considered as a four tact structure on the base of transistors of different polarity and its analysis is conducted. Application of such structure at symmetry of it shoulders substa...

Download PDF file
  • EP ID EP308229
  • DOI 10.20535/RADAP.2017.68.54-58
  • Views 84
  • Downloads 0

How To Cite

O. Panichev, A. Popov, V. Kharytonov (2017). Comparison of epileptic seizure prediction performance for different EEG derivation schemes. Вісник НТУУ КПІ. Серія Радіотехніка, Радіоапаратобудування, 0(68), 54-58. https://europub.co.uk/articles/-A-308229