Comparison of Morphology of Intracranial Aneurysms on Computed Tomography Angiography with Digital Subtraction Angiography and Intraoperative Findings–A Single Centre Experience
Journal Title: Journal of Clinical and Diagnostic Research - Year 2019, Vol 13, Issue 1
Abstract
ABSTRACT Introduction: Multi-Detector Computed Tomography (MDCT) angiography is a non-invasive technique in emergency screening of Subarachnoid Haemorrhage (SAH) for accurately detecting aneurysms. Digital Subtraction Angiography (DSA) remains the gold standard for diagnosis of intracranial aneurysm. Computed Tomography Angiography (CTA) is being increasingly used for this purpose and can presently replace DSA as the most reliable means to detect intracranial aneurysms in SAH. Aim: To characterise the morphology of intracranial aneurysms with CTA and to compare it with DSA and intraoperative findings. Materials and Methods: This analytical study includes patients suspected to have intracranial aneurysm and underwent CTA on 16 slice MDCT scanner. Post-processing Multiplanar Reconstructions (MPR), 3D Volume Rendering (VR) and Maximum Intensity Projection (MIP) were performed. The findings of CTA findings were compared with DSA and intraoperative/indocyanine angiography images obtained by Leica neurosurgical operating microscope, wherever possible. Morphological parameters: size (dome, neck, height, dome to neck ratio, aspect ratio in saccular and length, diameter in fusiform), shape, lobulation, tit, location, thrombosis/calcification, blood vessels arising, ruptured or not, grade of SAH (modified CT Fischer score) and vasospasm (grade, number/location of vasospastic segments) were assessed and compared with DSA and intraoperative findings. Results: In 71 patients, 97 intracranial aneurysms were studied. Saccular aneurysm was the most common and anterior communicating artery (ACOM) was the most common location. Significant correlation of dome: neck and aspect ratios between CTA and DSA (p=0.0089) was noted. The sensitivity, Positive Predictive Value (PPV) and accuracy of CTA for aneurysm >3 mm was 100%. Two aneurysms <3 mm were missed on CTA, but detected by DSA. Therefore, for aneurysms <3 mm in size, sensitivity was 92.86%, with a PPV and accuracy of 96.3% and 89.66%, respectively. Overall sensitivity of CTA irrespective of size was 97.9%, with 97.9% PPV and 95.9% accuracy was observed. Conclusion: MDCTA with 3D reconstructions and volume rendering is the ideal first line imaging modality in non-traumatic SAH for detection of aneurysm with a high degree of accuracy. DSA can be used to diagnose tiny aneurysms <3 mm if missed on CTA, if there is a high degree of suspicion.
Authors and Affiliations
Santosh PV Rai, Parvrvathi Chandran, Muralidhar Pai, Mayur Kamath, Keerthiraj Bele, Ashvini Kumar, Shrijeet Chakraborti
A Rare Case of Poorly-Differentiated Sertoli Leydig Cell Tumour of Ovary with Mesenchymal Heterology
Abstract Sertoli–Leydig Cell Tumours (SLCT) accounts for less than 0.5% of all ovarian neoplasms. Presence of mesenchymal heterologous elements in a poorly differentiated SLCT is extremely uncommon. It not only causes di...
Fabrication of Conventional Complete Denture in Resorbed Mandibular Ridge with Deficient Keratinized Mucosa Using Free Gingival Graft
ABSTRACT Long standing edentulism often results in dimensional changes in the bone as well as in the soft tissue. The severity of these changes depends upon the span of edentulism, systemic and oral well-being of the pat...
Varied Clinical Spectrum of a Rare Entity Pneumonia-Pasteurella canis: Case Series and Review of the Literature
ABSTRACT Pasteurella canis is a gram-negative coccobacillus belonging to the Pasteurellaceae family. Pasteurella species are prevalent among many animals where they are present as part of normal microbial flora of oral,...
Staged Hard and Soft Tissue Reconstruction Followed by Implant Supported Restoration in the Aesthetic Zone: A Case Report
Alveolar ridge deficiency is a common clinical consequence following tooth loss due to chronic periodontitis complicating ideal implant placement. Advanced hard and soft tissue augmentation procedures have been developed...
Light Emitting Diode Lighting Flicker, its Impact on Health and the Need to Minimise it
ABSTRACT The existing technologies in Light Emitting Diode (LED) lighting sometimes cause flicker at frequencies that may have adverse health effects. Although, not always obvious to the human eye, it can make a differen...