COMPARISON OF NUMBER OF DIFFUSION GRADIENT DIRECTION IN BRAIN IMAGING DIFFUSION TENSOR; CASE STUDY OF TUMOR BRAIN

Journal Title: Journal of Vocational Health Studies - Year 2017, Vol 1, Issue 1

Abstract

Background : Diffusion Tensor Imaging (DTI), namely MRI sequence which is the diffusion of water analysis that shows the complex structure of brain tissue. The weakness of this sequence is scanning time. Number of Diffusion Gradient Direction (NDGD) is one of parameter that effect scanning time. Purpose: This study has aim to compare between NDGD 25 and NDGD 15 in brain tumor. Methods: This study used observational analytic study with prospective approach. Five patients were examined using DTI sequence with NDGD 25 and NDGD 15. The parameter for evaluating the quality image is of Fractional Anisotropy (FA) and Fiber Tracking (FT). Result: Image with NDGD 25 was better than NDGD 15, but the difference was not significantly. Conclusion: It can be concluded that NDGD 15 can be solution to get informative image with short scan time when DTI sequence is used to examine brain tumor.

Authors and Affiliations

Afif Rofiky, Paulus Rahardjo, Didik Soeharmanto

Keywords

Related Articles

MANUFACTURING TECHNIQUE OF METAL CERAMIC RESTORATION WITH IMPLANT-ABUTMENT AT GINGIVAL RESORPTION CASE

Background: The low levels of patient satisfaction and confidence in the restoration of the gingival resorption results in impaired quality of life in both functional and psychosocial aspects. It is necessary to manufact...

SCORING ANALYSIS OF THE RELATIONSHIP BETWEEN MAGNETIC RESONANCE IMAGING- ANXIETY QUESTIONNAIRE (MRI-AQ) WITH HEART RATE TO PATIENTS ANXIETY LEVEL AT LUMBOSACRAL MRI EXAMINATION

Background: Anxiety during MRI examination becomes a common constraint and can have a negative effect that is the quality of the resulting image due to the existence of motion artifacts until the failure of the examinati...

LEVEL OF SAFE BEHAVIOR WITH THE IMPLEMENTATION OF HOT WORK PERMIT APPROACH IN PT BBB EAST JAVA

Background: The causes of the accident were dominant due to unsafe behavior and other causes due to unsafe conditions and the other factors, especially in the paper industry such as PT. BBB, East Java which has a high ri...

ANALYSIS OF FRACTIONAL ANISOTROPY (FA) VALUES AND APPARENT DIFFUSION COEFFICIENT (ADC) VALUES IN ISCHEMIC STROKE DISEASES OF MRI GE 3 TESLA

Background: Diffusion Weighted Imaging and Diffusion Tensor Imaging is an advanced technique in MRI that shows the diffusion in brain of ischemic stroke disease. Diffusion Weighted Imaging (DWI) shows the lesions without...

REDUCTION OF CONSTIPATING SCORING SYSTEM AMONG WOMEN AGED 18-25 YEARS OLD AS A RESULT OF DECOCTED TRENGGULI (CASSIA FISTULA L.)

Background: Constipation is a condition when someone has difficulty to defecate. Constipation is indicated by hard and large size stool as well as a decrease frequency of bowel movement. Commonly, constipation is indicat...

Download PDF file
  • EP ID EP594024
  • DOI 10.20473/jvhs.V1.I1.2017.15-17
  • Views 392
  • Downloads 0

How To Cite

Afif Rofiky, Paulus Rahardjo, Didik Soeharmanto (2017). COMPARISON OF NUMBER OF DIFFUSION GRADIENT DIRECTION IN BRAIN IMAGING DIFFUSION TENSOR; CASE STUDY OF TUMOR BRAIN. Journal of Vocational Health Studies, 1(1), 15-17. https://europub.co.uk/articles/-A-594024