Comparison of Refractive Error Measurements between KR-1W Wavefront Analyser and KR-8800 Automatic Refractometer in School Children
Journal Title: Journal of Clinical and Diagnostic Research - Year 2018, Vol 12, Issue 6
Abstract
ABSTRACT Introduction: A number of methods and instruments, such as retinoscopy, Hartmann-Shack sensor, ray tracing method and rotary prism technology, are available for assessing refractive status in clinic. The literature on comparison of refractive error values between KR-1W wavefront analyser and KR-8800 automatic refractometer is not adequately available. Aim: To compare refractive error measurements taken by KR-1W wavefront analyser and KR-8800 automatic refractometer and study factors influencing the refractive error values, such as age and gender. Materials and Methods: As a prospective observational study, one eye of 57 school children underwent refractive error measurements with the sequence of KR-8800 and KR-1W with the time interval less than five minutes under no cycloplegic condition. The interdevice agreement was evaluated using the Bland-Altman analysis, Pearson correlation coefficient, and paired two-tailed t-test. Vector analysis was used to compare astigmatism measurements. Results: The spherical power values measured by the KR-8800 were significantly more negative about 0.16±0.51 diopter than those of the KR-1W (p=0.024). The cylinder power values measured by the KR-8800 were significantly more positive about 0.11±0.32 diopter than those of the KR-1W (p=0.014). Moreover, KR-8800 and KR-1W were significantly different in astigmatism measurements using vector analysis. There was a significant linear correlation between the KR-8800 and KR-1W instruments for the spherical error (r=0.974, p<0.0001), cylinder power (r=0.807, p<0.0001). The interdevice 95% Limits of Agreement (LoA) range for the spherical error and cylinder power were 2.02 D and 1.25 D, respectively. Age negatively correlated with spherical error and cylinder power and the spherical error showed much more negative correlation values than cylinder power. However, gender showed no significant correlations with neither spherical error nor cylinder power of both instruments. Conclusion: The spherical power and astigmatism showed significant difference between the KR-1W and KR-8800 devices. However, the measurements of the two instruments showed significant linear correlation to each other.
Authors and Affiliations
Jing Dong, Qiang Wu, Xiaogang Wang
Management of Chronic Blink Related Microtrauma in Stevens-Johnson Syndrome with Oral Mucous Membrane Graft Transplantation: A Novel Approach
A 26-year-old male was referred with sequel of Stevens-Johnson Syndrome (SJS) in form of bilateral severe keratinisation of lid margin and Symbhlepharon involving in particular forniceal region. At the time of presentati...
Azathioprine in Chronic Recalcitrant Erythema Nodosum Leprosum: A Case Report
Erythema Nodosum Leprosum (ENL) may have a chronic course which may be recalcitrant to treatment. Preferred treatment modalities are systemic corticosteroids and thalidomide. Azathioprine, methotrexate and cyclosporine a...
Home Based Blood Pressure Monitoring in Indian Setting: A Consensus Document
ABSTRACT Hypertension is one of the most significant public health problem and a common lifestyle disease today in India. Monitoring of blood pressure along with appropriate and timely management is critical in order to...
Colour Change and Surface Gloss of Unpolished Infiltrated Bovine Enamel Submitted to Toothbrushing, pH Cycling and Artificial Ageing
ABSTRACT Introduction: The first clinical sign of a caries lesion which represents mineral loss from the enamel subsurface is white spot lesion. Thus, the use of a resin infiltrant has been cited as a promising treatment...
Late Onset Atypical Eclampsia: A Case Report
ABSTRACT Hypertensive disorders in pregnancy account for substantial maternal and peri-natal morbidity and mortality. Atypical eclampsia presents as a diagnostic dilemma and challenge for the treating obstetrician. The p...