Comparison of the effects of two different dose algorithms in cardiac dose parameters for hodgkin lymphoma patients receiving mediastinal radiotheraphy

Journal Title: Medical Science and Discovery - Year 2016, Vol 3, Issue 8

Abstract

Objective:  This study aimed to compare pencil beam (PB) and convolution superposition (CS) dose calculation algorithms with respect to cardiac dose-volume parameters V5, V25, V30 and MHD (median heart dose) in Hodgkin lymphoma (HL) patients who received mediastinal radiotherapy (RT).Material and Methods:  Ten eligible cases with the diagnosis of HL who completed mediastinal RT at Dokuz Eylül University Department of Radiation Oncology before 01.01.2011 formed the study population.  Related 3D conformal RT treatment plans were obtained from the Treatment Planning System (TPS) (Nucletron Oncentra Master Plan Version 3.3 SP3 program). Calculations were done for 6 and 18 MV-X beam energy, respectively by using PB and CS algorithms in the TPS. Two algorithms were compared in terms of cardiac dose-volume parameters (V5, V25, V30 and MHD).Results: Mean relative difference for both V25 and V30 was found to be significantly higher in favor of PB algorithm in both 6 MV-X and 18 MV-X photon energy.  Mean relative differences were 1.75% (p=0.012) and 6.76% (p=0.028) for the V25 and V30 parameters, respectively in 6 MV-X and 3.25% (p=0.021) and 13.95% (p=0.007) for the V25 and V30 parameters, respectively in 18 MV-X energy.Conclusion:  When PB algorithm is used in RT treatment planning of HL patients for the mediastinal region where tissue inhomogeneity is relatively high, heart V25 and V30 parameters were shown to result in higher values compared to CS algorithm in our study.  It is more appropriate to prefer CS algorithm instead of  PB algorithm since it increases accuracy of calculations in the treatment planning of mediastinal RT.

Authors and Affiliations

Emre Tahberer, Ahmet Cinkaya, Yasin Coban, Serdar Surenkok, Mehmet Adigul, Ahmet Ergin Capar

Keywords

Related Articles

A mortal accident caused by a broken toilet seat cover

According to hospital records, a 36 years old, 1.75 m in length, average weight man was brought to Izmir Bozyaka Training and Research Hospital by 112 ambulance at 01/07/2011, 21:20 PM with an injury caused by fracture o...

Antibacterial Activity of Laurus nobilis: A review of literature

The presence of phenolic compounds in spices and herbs, along with the essential oils, has been gaining attention due to their various functions like antioxidant capacity, antimicrobial properties, and flavoring properti...

Coronary artery bypass surgery and sexual function

Objectives:To evaluate the influences of coronary artery by-pass surgery(CABS) on sexual function(SF) and the comorbidities on the impact of CABS on SF.Methods:The data of 112 patients who underwent CABS and interviewed...

Study of Matrix Gla Protein G-7A and T-138C Gene Polymorphisms in Patients with Type 2 Diabetes Mellitus

Objective: Type 2 diabetes mellitus is a major risk factor for aortic calcifications and cardiovascular disease (CVD).  Matrix Gla proteins (MGP) have a significant role in control of the process of calcification. The pu...

EFFECT OF PROPOFOL AND MEMANTINE ON ERYTHROCYTE DEFORMABILITY IN DIABETIC RAT MODEL

OBJECTIVES: In this study we aimed to investigate the effect of diabetes on erythrocyte deformability (ED) and whether it can be changed by an NMDA antagonist propofol or an NMDA agonist, memantineBACKGROUND: Several cli...

Download PDF file
  • EP ID EP520527
  • DOI 10.17546/msd.57676
  • Views 41
  • Downloads 0

How To Cite

Emre Tahberer, Ahmet Cinkaya, Yasin Coban, Serdar Surenkok, Mehmet Adigul, Ahmet Ergin Capar (2016). Comparison of the effects of two different dose algorithms in cardiac dose parameters for hodgkin lymphoma patients receiving mediastinal radiotheraphy. Medical Science and Discovery, 3(8), 301-4. https://europub.co.uk/articles/-A-520527