Comparison of the haemodynamic responses to laryngoscopy and intubation with MacIntosh and McCoy laryngoscopy

Journal Title: Journal of Medical Science And clinical Research - Year 2017, Vol 5, Issue 7

Abstract

Background: Stress response to laryngoscopy and tracheal intubation have a profound influence on the circulatory parameters and the intracranial pressure. The mean increase in arterial pressure of the order of 20-25 mmHg with a maximum rise of 40-45 mmHg has been reported. This peak response occurs approximately 30-45 seconds after laryngoscopy and lasts less than ten minutes. Forces transmitted by the laryngoscope blades on the base of the tongue are assumed to be a major stimulus. Sympathoadrenal response arises from the stimulation of the supraglottic region by the laryngoscope blade. When planning the anaesthesia induction, these effects must be blunted as much as possible. Materials and Methods: This observational study was conducted at SMHS hospital of government medical college Srinagar. The study was conducted over a period of one year and total number of 100 patients were scheduled for elective procedures by randomly allocating to either Macintosh or McCoy laryngoscopy group. Aim was to Comparision of haemodynamic responses between the two groups. Comparing the time of laryngoscopy and intubation between the two groups and Comparing the laryngeal visualization grading between two groups. An informed written consent was taken from all patients at the time of pre-anaesthetic examination. Laryngoscopy and intubation was performed by standardized anesthetic technique. Size 3 laryngoscope blade was used in all cases. Monitoring include: measurement of noninvasive BP, heart rate (HR), any dysrhythmia .oxygen saturation, end-tidal carbon dioxide, concentration of inhalational anesthetic agent. All values were recorded before induction, immediately before and after laryngoscopy and tracheal intubation, every minute for 5 min following tracheal intubation, and then 10 min after intubation. Results: The baseline characteristics of the patients in terms of age, weight, height, sex distribution, Mallampati grading and the difference was not statistically significant similar between both the groups which indicated that both the groups were comparable. Maximal rise in heart rate was seen immediately post insertion with mean (107.9) in group A and mean (97.2 ) in group B respectively, and maximal value of standard deviation was seen after 3 min after insertion 4.34 in group A and 4.29 in group B. On comparison of blood and mean arterial pressure between two groups blood and mean arterial pressure was lower in group B with p statistically significant immediately post insertion,1 min and 3 min, and p is statistically insignificant after 5min. Conclusion: McCoy laryngoscope produces significantly less rise in hemodynamic parameters as compared to Macintosh laryngoscope during laryngoscopy and intubation.

Authors and Affiliations

Dr Naqeeb Hassan

Keywords

Related Articles

Variations in the Termination of Cystic Duct by gross Dissection Method: A Report of 100 Cases of Odishan Population

Introduction: The Cystic duct is about 3 cm in length but variable. It terminates usually in the supraduodenal region into the R.H.D .But on many occasions it displays aberrations from the normal. The study is an attempt...

Proportion of Raised Blood Pressure and Raised Blood Sugar Level in Newly Diagnosed Attention Deficit Hyperactivity Disorder in Children

ADHD is now considered as a disease spanning the life span. The physical co morbidities of ADHD has not been yet studied adequately .It is unknown whether ADHD is associated with any childhood or adolescent variation in...

Hypoplastic Right Heart Syndrome is a Rare Disorder – Case Report

Hypoplastic Right Heart Syndrome (HRHS) is a condition that is even more rare than Hypoplastic Left Heart Syndrome (HLHS). HRHS refers to the underdevelopment of the right side structures of the heart, which means that t...

Effect of Haemodialysis on Elevated Serum lipid profile in cases of Chronic Kidney Disease

Alteration in the lipid metabolism has been reported to occur in subject of uraemia. 50 cases of chronic kidney disease were included for study. Patients were put in regular haemodialysis and effects of haemodialysis on...

Spectrum of CT Angiographic Findings in a Series of 114 Patients of Clinically Suspected Cases of Takayasu Arteritis – A Prospective Study at a Teritiary Care Hospital in India

Aims & Objectives: 1) To detect various angiographic patterns by CT angiography in clinically suspected 114 cases of Takayasu’s arteritis.2)To characterize & classify the lesions into various subgroups 3) To evaluate dia...

Download PDF file
  • EP ID EP527808
  • DOI -
  • Views 45
  • Downloads 0

How To Cite

Dr Naqeeb Hassan (2017). Comparison of the haemodynamic responses to laryngoscopy and intubation with MacIntosh and McCoy laryngoscopy. Journal of Medical Science And clinical Research, 5(7), 25795-25804. https://europub.co.uk/articles/-A-527808