Comparison of the signal characteristics measured by a MEMS and a Piezoelectric accelerometers

Abstract

This study is dedicated to verifying the performance of a MEMS accelerometer when used for machine condition monitoring based on vibration analysis. The performance of the MEMS accelerometer was compared to that of a piezoelectric sensor, traditionally used in this type of analysis. This goal was reached by measuring the RMS, Kurtosis and Crest levels of the signal obtained by the MEMS sensor against those obtained by the piezoelectric sensor under the same excitation parameters. Both the piezoelectric sensor and the MEMS circuit board were mounted on a special device attached to a shaker. The sensors were submitted to vibrations of 0.5g, 1g and 2g RMS on a frequency ranging from 1Hz up to 2500Hz on steps of 20Hz. The results show that the readings of the MEMS sensor present a maximum deviation of 6.6% when compared to the piezoelectric sensor. It was possible to conclude that a great portion of the deviation encountered was due to the dynamic characteristics of the mounting device and the fixation conditions of the MEMS sensor on this device

Authors and Affiliations

Keywords

Related Articles

Experimental Planning Factorial: A brief Review

The optimization of experimental relevance parameters can be considered one of the most critical steps in a scientific work according to the chosen model may contribute to a result that does not match the true great. Thu...

Estimation of Rainfall-Runoff Relationship Using Artificial Neural Network Models for Muskegon Basin

In order to determine the use, protection and economic life of water resources; it is important to make estimations about rainfall-runoff values. However, it is quite complicated to estimate rainfall-runoff. For this rea...

The Creation of a Vortex in Sea water through the MHD

The Magneto hydrodynamics equations, MHD, are discussed for weakly conductive fluids of electricity, and then an analytical solution is presented. An MHD vortex is generated using seawater in a cylindrical vessel, where...

Site Design of Public Space under the Jenggolo Sidoarjo Flyover, East Java is reviewed from the Location Characteristics

This public open space under the Sidoarjo jenggolo flyover is known to be not optimal in its operations, both from zoning arrangements, number of visitors, and types of activities. Based on the results of the analysis, t...

Statistical Analysis of Rainfall Event in Seonath River Basin Chhattisgarh

To understand the mechanism of potential hydrologic impacts of climate and land use land cover changes. In this study identified to the significant temporal trend was carried out monthly, seasonal timescales. Using the r...

Download PDF file
  • EP ID EP504348
  • DOI 10.22161/ijaers.5.11.21
  • Views 49
  • Downloads 0

How To Cite

(2018). Comparison of the signal characteristics measured by a MEMS and a Piezoelectric accelerometers. International Journal of Advanced Engineering Research and Science, 5(11), -. https://europub.co.uk/articles/-A-504348