Comparison of Torque Control and Anchorage Loss Using Two Different Pre-Adjusted Edgewisebracket Systems

Journal Title: IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) - Year 2018, Vol 17, Issue 6

Abstract

Predictable and controlled tooth movement is the goal of every orthodontist.Fixed appliance therapyis one of the treatment options for malocclusion During the aligning stage, the increased inter bracket span leads to faster and efficient alignment but at the same could be a disadvantage during the space closure because of the reduced arch wire bracket contact area that would lead to reduced control of the torque of the anteriors. The unique design of the mini uni-twin that incorporates an increased inter bracket span of the single width bracket but at the same has the rotational control of a double width bracket. Objectives: To compare the torque control and anchorage loss using double width brackets and mini uni twin brackets in Roth prescription. Method: Comparative study with 20 subjects (10 in each group) with Angle's Class I dento-alveolar malocclusion were randomly selected for the study. Results: The anchorage loss was comparatively similar in both. The torque control of incisor during retraction was better in double width brackets when compared to Mini Uni Twin brackets. The latter may be efficient during alignment and leveling but comparatively less efficient for torque control during the retraction of anterior teeth.

Authors and Affiliations

Anand R Krishnan, Asish R, Vinimol C

Keywords

Related Articles

Impacts of Orthodontic Treatment on Periodontium: A Review

With a number of patients opting for orthodontic therapy for esthetic reasons, it becomes necessary to evaluate the resulting effects of orthodontic treatment on the periodontal tissues. In many cases, orthodontic tooth...

A Quandary for Atypical Canal Pattern in Mandibular Second Premolar: A Case Report

Success of endodontic treatment requires the knowledge and morphology of root canal anatomy. Undetected additional canals in mandibular premolar is a common reason for endodontic failure. This presents with diagnostic di...

Orbital Metastasis An Analysis of Nine Cases And Review of Literature

Aim: To analyze nine cases of orbital metastasis with review the literature for incidence, presentation, evaluation and discuss their multidisciplinary management. Materials and Methods: Retrospective study of nine patie...

Retinopathy of Prematurity: Prevalence, risk factors and comorbidities

Retinopathy of prematurity (ROP) is a disorder of retinal vasculature, characterized mainly by abnormal development of retinal vasculature and is an important and preventable cause of childhood blindness1 . It usually af...

A Prospective Study Showing Results of Displaced Distal Clavicle Fractures Treated With K-Wires And Tension Band Wires.

Non-union frequently follows distal clavicle fracture. Several surgical techniques have been developed in order to reduce the non-union rate and improve functional outcome. This study shows result of tension band wiring...

Download PDF file
  • EP ID EP376601
  • DOI 10.9790/0853-1706093035.
  • Views 51
  • Downloads 0

How To Cite

Anand R Krishnan, Asish R, Vinimol C (2018). Comparison of Torque Control and Anchorage Loss Using Two Different Pre-Adjusted Edgewisebracket Systems. IOSR Journal of Dental and Medical Sciences (IOSR-JDMS), 17(6), 30-35. https://europub.co.uk/articles/-A-376601