Comparison of Wear Resistance of Hawley and Vacuum Formed Retainers: An in-vitro Study
Journal Title: Journal of Dental Biomaterials - Year 2016, Vol 3, Issue 2
Abstract
Statement of Problem: As a physical property, wear resistance of the materials used in the fabrication of orthodontic retainers play a significant role in the stability and long term use of the appliances. Objectives: To evaluate the wear resistance of two commonly used materials for orthodontic retainers: Acropars OP, i.e. a polymethyl methacrylate based material, and 3A-GS060, i.e. a polyethylene based material. Materials and Methods: For each material, 30 orthodontic retainers were made according to the manufacturers’ instructions and a 30×30×2 mm block was cut out from the mid- palatal area of each retainer. Each specimen underwent 1000 cycles of wear stimulation in a pin on disc machine. The depth of wear of each specimen was measured using a Nano Wizard II atomic force microscope in 3 random points of each specimen’s wear trough. The average of these three measurements was calculated and considered as mean value wear depth of each specimen (µm). Results: The mean wear depth was 6.10µm and 2.15µm for 3A-GS060 and Acropars OP groups respectively. Independent t-test showed a significant difference between the two groups (p < 0.001). The results show Polymethyl methacrylate base (Acropars) is more wear resistance than the polyethylene based material (3A-GS060). Conclusions: As the higher wear resistance of the fabrication material can improve the retainers’ survival time and its cost-effectiveness, VFRs should be avoided in situations that the appliance needs high wear resistance such as bite blocks opposing occlusal forces.
Authors and Affiliations
V Moshkelgosha, M Shomali
Introducing a Dental Caries Marking Software and Evaluate Radiologists’ Disagreement in Caries Detection Using this Software
Statement of Problem: Bitewing radiograph is the main reference for diagnosis of proximal and recurrent caries. There is no software for gathering and analyzing radiologists’ opinion in the field of caries detection on d...
The Role of Home Bleaching Agent on the Fracture Toughness of Resin Composites Using Four-Point Bending Test
Statement of Problem: Resin composites are a common type of tooth coloured restorative materials. These materials are brittle and their major shortcomings are sensitivity to flaws and defects, low tensile strength, and s...
Finite Element Analysis of the Effect of Superstructure Materials and Loading Angle on Stress Distribution around the Implant
Statement of Problem: A general process in implant design is to determine the reason of possible problems and to find the relevant solutions. The success of the implant depends on the control technique of implant biomech...
Comparison of Mechanical Properties Between three Different Types of T-loop
Statement of Problem: T-loop is one of the most popular closing loops in orthodontic profession. However its activation is in the contrary to Bouschinger effect theory, since the formed bends would be opened during activ...
Bioactive Glasses in Dentistry: A Review
Bioactive glasses are silicate-based and can form a strong chemical bond with the tissues. These biomaterials are highly biocompatible and can form a hydroxyapatite layer when implanted in the body or soaked in the simul...