Compliance of Some Quality Control Parameters of Diagnostic Xray Equipment in Three Selected Tertiary Hospitals in South East, Nigeria to a known standard.

Journal Title: IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) - Year 2018, Vol 17, Issue 10

Abstract

Introduction: Periodic monitoring of X-ray equipment quality control parameters is very important to ensure precision and accuracy of radiographic tests. Aim: The aim of this study is to assess the compliance of some quality control (QC) parameters of some conventional X-ray equipment to a known standard. Settings and Design: Setting was in Nigeria and a cross sectional design was used. Method and Material: Material used was a non-invasive digital multifunctional detector meter (MDM). Three facilities were selected from a university teaching hospital. Measurement of KVp, mAs and the exposure time accuracy was performed using MDM that incorporates computer output. The MDM was positioned at the center of the collimated beam axis with a Source to Image Distance (SID) of one meter. Eight different mAs, exposure times and KVp stations were selected and measured in each teaching hospital. Statistical Analysis: SPSS was used and statistical tools used was one way ANOVA The result obtained showed that the magnitude of deviation in KVp accuracy ranged from 0.01 to 6.07 % in all the four machines checked while the magnitude of deviation in mAs accuracy ranged from 0.00 to 19.20 %. In a similar way, exposure time accuracy deviated from 0.01 to 12.32 %. Conclusion: The study revealed that only one out of the four X-ray units at the teaching hospital in the Southern-Eastern part of Nigeria failed exposure time, mAs and KVp accuracy compliance test. K

Authors and Affiliations

Nnamdi F. Nworah, Christian C. Nzotta, Uche H. Chiegwu, Michael E. Aronu, Emmanuel O. Oyekunle

Keywords

Related Articles

Solid Pseudopapillary Tumor of Pancreas in Elderly Female – A Rare Case Report

Solid pseudopapillary tumor (SPT) is a rare tumor of pancreas usually presenting in young females. Here we present a case of SPT in an elderly female. A 73 year old female presented with upper abdominal pain. Computed To...

Grading of Brain Tumors using MR Spectroscopy: Diagnostic value at Short and Long TE

Objectives: To evaluate the usefulness of MR spectroscopy (MRS) in grading of brain tumors as well to evaluate which metabolite values/ratios could provide better classification/grading of brain tumors when using, short...

Hydrocoele Surgery Under Local Anesthesia: Practical Or Painful

Background: Vaginal hydrocoele is abnormal collection of serous fluid in the tunica vaginalis or a patent processus vaginalis. It is one of the common causes of scrotal swellings in all age group and frequently encounter...

Comparison of Safety and Efficacy of Streptokinase and Tenecteplase in Patients of Myocardial Infarction

Myocardial infarction is a major cause of mortality and morbidity worldwide. STEMI [ST segment elevation myocardial infarction] is a medical emergency condition. Reperfusion therapy like PCI [Percutaneous Coronary Interv...

Comparative Study of FAST Scaning in Diagnosis of Haemoperitonium and Comparision With Laprotomy Finding In Abdominal Trauma - A Prospective Study

The focused abdominal sonogram in trauma (FAST) is a focused, goal directed, sonographic examination of the abdomen aimed at detecting the presence or absence of haemoperitoneum. Aims and objectives:To determine the impo...

Download PDF file
  • EP ID EP401635
  • DOI 10.9790/0853-1710044447.
  • Views 31
  • Downloads 0

How To Cite

Nnamdi F. Nworah, Christian C. Nzotta, Uche H. Chiegwu, Michael E. Aronu, Emmanuel O. Oyekunle (2018). Compliance of Some Quality Control Parameters of Diagnostic Xray Equipment in Three Selected Tertiary Hospitals in South East, Nigeria to a known standard.. IOSR Journal of Dental and Medical Sciences (IOSR-JDMS), 17(10), 44-47. https://europub.co.uk/articles/-A-401635