Compliance of Some Quality Control Parameters of Diagnostic Xray Equipment in Three Selected Tertiary Hospitals in South East, Nigeria to a known standard.
Journal Title: IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) - Year 2018, Vol 17, Issue 10
Abstract
Introduction: Periodic monitoring of X-ray equipment quality control parameters is very important to ensure precision and accuracy of radiographic tests. Aim: The aim of this study is to assess the compliance of some quality control (QC) parameters of some conventional X-ray equipment to a known standard. Settings and Design: Setting was in Nigeria and a cross sectional design was used. Method and Material: Material used was a non-invasive digital multifunctional detector meter (MDM). Three facilities were selected from a university teaching hospital. Measurement of KVp, mAs and the exposure time accuracy was performed using MDM that incorporates computer output. The MDM was positioned at the center of the collimated beam axis with a Source to Image Distance (SID) of one meter. Eight different mAs, exposure times and KVp stations were selected and measured in each teaching hospital. Statistical Analysis: SPSS was used and statistical tools used was one way ANOVA The result obtained showed that the magnitude of deviation in KVp accuracy ranged from 0.01 to 6.07 % in all the four machines checked while the magnitude of deviation in mAs accuracy ranged from 0.00 to 19.20 %. In a similar way, exposure time accuracy deviated from 0.01 to 12.32 %. Conclusion: The study revealed that only one out of the four X-ray units at the teaching hospital in the Southern-Eastern part of Nigeria failed exposure time, mAs and KVp accuracy compliance test. K
Authors and Affiliations
Nnamdi F. Nworah, Christian C. Nzotta, Uche H. Chiegwu, Michael E. Aronu, Emmanuel O. Oyekunle
Post Endodontic management of a critically traumatized Central Incisor: An extreme save
The management of adult patients with traumatic injuries to their dentition poses a serious challenge in everyday general dental practice. For the rehabilitation of the complicated subgingival crown fracture of anterior...
A Critical Analysis of Variation In The Prices of HMG CoA Reductase Inhibitors Available In Indian Market
.
Prevalence of Positive Widal test in comparison with clinical request in a tertiary care teaching hospital, West Bengal
Introduction: Enteric fever which includes typhoid and paratyphoid fever is a systemic febrile illness caused by the bacterium Salmonella entericaserovartyphi and paratyphi A, B, C respectively. Widal test is almost the...
A Comparative Study of Efficiency Between Anal Fissurectomy And Partial Internal Sphincterotomy For Chronic Anal Fissure
One hundred patients with chronic anal fissure were admitted to the surgical wards of S.V.R.R.G.G. Hospital, Tirupati during the period of August 2016 to November 2017, treated by Anal Fissurectomy or Partial Closed Inte...
Evaluation Of The Role Of Diagnostic Laparoscopy Innon Specific Abdominal Pain & Its Correlation With Clinical & Radiographic Findings
BACKGROUND: Non specific abdominal pain is a diagnostic challenge; such patients frequently seen by many physician & undergoing vast diagnostic workup without making definitive diagnosis at the end & got unsatisfactory d...