Compliance of Some Quality Control Parameters of Diagnostic Xray Equipment in Three Selected Tertiary Hospitals in South East, Nigeria to a known standard.

Journal Title: IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) - Year 2018, Vol 17, Issue 10

Abstract

Introduction: Periodic monitoring of X-ray equipment quality control parameters is very important to ensure precision and accuracy of radiographic tests. Aim: The aim of this study is to assess the compliance of some quality control (QC) parameters of some conventional X-ray equipment to a known standard. Settings and Design: Setting was in Nigeria and a cross sectional design was used. Method and Material: Material used was a non-invasive digital multifunctional detector meter (MDM). Three facilities were selected from a university teaching hospital. Measurement of KVp, mAs and the exposure time accuracy was performed using MDM that incorporates computer output. The MDM was positioned at the center of the collimated beam axis with a Source to Image Distance (SID) of one meter. Eight different mAs, exposure times and KVp stations were selected and measured in each teaching hospital. Statistical Analysis: SPSS was used and statistical tools used was one way ANOVA The result obtained showed that the magnitude of deviation in KVp accuracy ranged from 0.01 to 6.07 % in all the four machines checked while the magnitude of deviation in mAs accuracy ranged from 0.00 to 19.20 %. In a similar way, exposure time accuracy deviated from 0.01 to 12.32 %. Conclusion: The study revealed that only one out of the four X-ray units at the teaching hospital in the Southern-Eastern part of Nigeria failed exposure time, mAs and KVp accuracy compliance test. K

Authors and Affiliations

Nnamdi F. Nworah, Christian C. Nzotta, Uche H. Chiegwu, Michael E. Aronu, Emmanuel O. Oyekunle

Keywords

Related Articles

Microorganisms Isolated from Port Site Infection: AclinicoMicrobiological Study

Background: Port-site infection (PSI) is a prevailing, chronic, nagging, treatment refractory complication of laparoscopic cholecystectomies. It neutralizes the advantages of minimally invasive surgery and increases morb...

4-Pin Technique of Management of Distal Both Bone Fracture of Forearm in Elderly

Introduction: Distal both bone fractures are one of the most common injury of an elderly who falls with flexed elbow, landing on the wrist. There is a wide variety of treatment options such as closed reduction and POP ca...

“Observations of Serum Magnesium Levels in Major Burns”

To observe the Serum magnesium levels in 25 cases of major burns. 25 cases of Major burn of varying degree from different ages & sex admitted in Burn ward of Rajendra Institute of Medical Sciences, Ranchi were taken up f...

Knowledge and Attitude of School Teachers towards the Management of A Knocked Out Tooth

Aim: This study was designed to examine the knowledge and attitude of school teachers with regard to emergency management of an avulsed permanent tooth. Materials and methods: The survey was conducted among 97 school tea...

Medical-Education Strengthening By Inclusion Of Dental- Education Is An Utmost Necessity In INDIA & World: A Perspective

In many countries, the present standing of the Dental-Education split from the Medical-Education is not good & satisfactory towards providing healthcare to their citizens. It seems that it has evolved due to deficient kn...

Download PDF file
  • EP ID EP401635
  • DOI 10.9790/0853-1710044447.
  • Views 52
  • Downloads 0

How To Cite

Nnamdi F. Nworah, Christian C. Nzotta, Uche H. Chiegwu, Michael E. Aronu, Emmanuel O. Oyekunle (2018). Compliance of Some Quality Control Parameters of Diagnostic Xray Equipment in Three Selected Tertiary Hospitals in South East, Nigeria to a known standard.. IOSR Journal of Dental and Medical Sciences (IOSR-JDMS), 17(10), 44-47. https://europub.co.uk/articles/-A-401635