Consistency of Fractional Anisotropy Values Using Different Combinations of b-Value and Time of Echo (TE) in Diffusion Tensor Imaging of Normal Brain White Matter

Journal Title: Journal of Clinical and Diagnostic Research - Year 2018, Vol 12, Issue 12

Abstract

ABSTRACT Introduction: Fractional Anisotropy (FA) values are considered as a solid concrete index for determining white matter integrity in ageing and neurodegenerative diseases. FA is more comparable and reliable parameter than individual diffusivity parameters. A b-value and Time of Echo (TE) significantly affect the reproducibility and accuracy of Diffusion Tensor Imaging (DTI) derived indices at 1.5 Tesla (T) MRI machines in grey and white matter. Hence, no fixed b-value and TE protocol combination is recommended in literature to obtain consistent FA values, as it is a relatively new imaging technique. Aim: To check the consistency of FA values using different combinations of b-value and TE in DTI of normal brain white matter and to establish a standardised protocol for calculating FA values in different regions of normal brain white matter of the corpus callosum, centrum semiovale and pons. Materials and Methods: A cross-sectional study of 23 healthy participants without neurological abnormalities using 1.5 T MRI, DTI of brain white matter was performed. FA values were measured at the corpus callosum, centrum semiovale and pons using fiber track analysis in six different combinations of b-value and TE. Results: The FA values with least coefficient of variation was found with a b-value of 1000 s/mm2 and TE 100 ms. Conclusion: The current study established a standardised protocol for calculating FA values in different regions of normal brain white matter of the corpus callosum, centrum semiovale and pons.

Authors and Affiliations

Rahul P Kotian, K Prakashini, Sreekumaran Nair, M Satish Babu

Keywords

Related Articles

Haemangioma with Multiple Phleboliths-A Rare Case

ABSTRACT Haemangiomas and venous malformations are formed due to disturbances during the developmental period of an embryo. Changes in blood flow dynamics within a haemangioma may induce thrombus formation and phlebolith...

Whole-Exomes Sequencing Delineates Gene Variants Profile in a Young Saudi Male with Familial Hypercholesterolemia: Case Report

Familial hypercholesterolemia is an autosomal dominant genetic disease characterized by earlier elevated Low-Density Lipoprotein (LDL) cholesterol levels and increased risk for premature Myocardial Infarction (MI). Albei...

MR Imaging of Rotator Cuff Tears: Correlation with Arthroscopy

Introduction: Rotator cuff tears are quite common and can cause significant disability. Magnetic Resonance Imaging (MRI) has now emerged as the modality of choice in the preoperative evaluation of patients with rotator c...

Microscopic Artefacts in Clinical Practice- A Diagnostic Dilemma

Clinical Microbiologists often come across strange structures during microscopic examination of clinical specimens which are often confused with and misreported as micro-organisms. We studied series of cases in a super s...

Effect of Upper Limb Neural Mobilization on Vibration Threshold and Hand Grip Strength in Asymptomatic Individuals: A Randomized Controlled Trial

Introduction: Neural Tissue Mobilization (NTM) is a common technique used in clinical presentation with increased neural mechanosensitivity and was found to improve signs and symptoms. However, there is dearth in the lit...

Download PDF file
  • EP ID EP526346
  • DOI 10.7860/JCDR/2018/38089.12315
  • Views 47
  • Downloads 0

How To Cite

Rahul P Kotian, K Prakashini, Sreekumaran Nair, M Satish Babu (2018). Consistency of Fractional Anisotropy Values Using Different Combinations of b-Value and Time of Echo (TE) in Diffusion Tensor Imaging of Normal Brain White Matter. Journal of Clinical and Diagnostic Research, 12(12), 1-4. https://europub.co.uk/articles/-A-526346