Contamination level of transvaginal ultrasound probes in standard setting: A meta-analysis

Journal Title: National Journal of Physiology, Pharmacy and Pharmacology - Year 2017, Vol 7, Issue 1

Abstract

Gynecologist should be aware of cross infection using transvaginal ultrasonography. In fact, the contamination was usually being underestimated. Disinfection and probe cover in transvaginal ultrasound remained controversial. This study was planned with the objective to review the pooled proportion of contamination and types of microbes contaminated after the standard procedure at transvaginal probe and characterize the methods of disinfection and type of cover probe used in transvaginal ultrasound. Comprehensive literature search was done in Medline (1966-2015), SCOPUS (2004-2015), EMBASE, and Cochrane Central Register of Controlled Trials along with reference lists of electronically retrieved studies. We considered all published English language articles. The author used search strategy with words such as transvaginal, ultrasound, probe, contamination, and infect. Full-text journals are more preferred, but the abstract only journal is considered based on if the data are provided in the abstract. Data of study design, contamination rate, ultrasound disinfection technique, and probe cover were being reviewed. The pooled proportion of microbes contamination and difference of disinfection and probe cover were determined using Stata 12 and Review Manager 5.4. From 110 studies, 13 studies were potentially eligible for systematic review. Pooled proportion of total microbes contamination was 31% (95% CI: 1-56%, I2: 99.14%, P = 0.00). This rate was found 50% in bacteria contamination and only 4% in virus contamination. The most prevalence bacteria were coagulase-negative Staphylococci. A similar contamination rate was found either using condom or specific cover as probe cover (both 3%, risk difference −0.04). Interestingly, some studies showed advantage of using gloves as probe covers and automated disinfectant machine as disinfection methods. Contamination rate, especially bacteria contamination, is still high even after using the standard disinfection procedure. Further research is needed to find new disinfection procedures to reduce the contamination rate.

Authors and Affiliations

Citra Aryanti

Keywords

Related Articles

Prevalence of cuff hypertension among overweight and obese subjects

Background: “Obesity is a lifestyle affliction, it is a side effect of poor habit and it can be reversed.” Obesity is defined either by increased waist circumference, waist-hip ratio, and/or body mass index. Overestimati...

Comparison of case-based learning and traditional lectures in physiology among first year undergraduate medical students

Background: Physiology is basic and applied medical science. The traditional system of teaching in physiology is teacher cantered with minimal participation from the students. Case-based learning (CBL) is a self-directed...

Correlation between body mass index and response to cold pressor test in young medical students in a tertiary care hospital

Background: Obesity is a rising problem in young adults and it predisposes to many diseases. Obesity and stress together can increase the risk to developing lifestyle diseases. Medical students are under stress. Aims and...

Anti-inflammatory activity of lisinopril in albino rats

Background: Angiotensin II (Ang II) is a product of renin angiotensin aldosterone system. Angiotensin-II regulates vascular tone, stimulates the release of pro-inflammatory cytokines, activates nuclear factor-kappa B, in...

High-resolution manometric features of achalasia of the cardia

Background: Achalasia of the cardia is a common esophageal motility disorder. High-resolution manometry is the gold standard for the diagnosis of achalasia. The body of the esophagus and the lower esophageal sphincter (L...

Download PDF file
  • EP ID EP286224
  • DOI 10.5455/njppp.2017.7.0307808092016
  • Views 62
  • Downloads 0

How To Cite

Citra Aryanti (2017). Contamination level of transvaginal ultrasound probes in standard setting: A meta-analysis. National Journal of Physiology, Pharmacy and Pharmacology, 7(1), 1-12. https://europub.co.uk/articles/-A-286224