Controller Implementation for PV Interconnection Based ThreePhase UPS Systems Operating Under Highly Nonlinear Loads

Abstract

This paper presents the design of a PV interconnection system based three-phase uninterruptible power supply (UPS) systems that are operating under highly nonlinear loads. The classical high-performance sinusoidal pulse width modulation (SPWM) control method is quite effective in controlling the RMS magnitude of the UPS output voltages. However, it is not good enough in compensating the harmonics and the distortion caused specifically by the nonlinear currents drawn by the rectifier loads. This study proposes a new design strategy that overcomes the limitations of the classical RMS control. It adds inner loops to the closed-loop control system. Simulink is used to analyze, develop, and design the controller using the state-space model of the inverter. By the implementation of PV system based inverter we are analyzing the efficiency of proposed model of SPWM. Simulation performance is evaluated for a three-phase 10 kVA transformer isolated UPS under all types of load conditions. In conclusion, the simulation results demonstrate that the controller successfully achieves the steady-state RMS voltage regulation specifications as well as the total harmonic distortion and the dynamic response requirements of major UPS standards.

Authors and Affiliations

P. Muni Sravani| M.Tech, Scholar, Dept of EEE, Prakasam Engineering College, Kandukur, D. Srilatha| Associate Professor, Dept of EEE, Prakasam Engineering College, Kandukur, M. Bala Subba Reddy| Associate Professor& H.O.D Dept of EEE, Prakasam Engineering College, Kandukur

Keywords

Related Articles

Enhancement of Power Quality by Using Shunt Hybrid Power Filter With TCR

This paper presents a thyristor-controlled reactor (TCR) in combination with a fifth-tuned LC passive filter and active power filter (APF) in order to compensate the reactive power and to reduce harmonics.In addition...

Seculation Routing With Fortification Wireless Networks

Wireless sensor networks having so many problems a number of solutios enough? security issues, discusses some existing solutions, and suggests possible research directions like key establishment secrecy,authenticatio...

To Improve The Security Of OLSR Routing Protocol Based On Local Detection Of Link Spoofing

We survey a particular DOS attack called node separation attack and propose another moderation technique. Our answer called Denial Contradictions with Fictitious Node Mechanism (DCFM) depends on the interior informat...

Sheltered Compound Vendor Data Apportioning For Vibrant Clusters In The Cloud

Cloud computing is an emerging computing paradigm in which resources of the computing infrastructure are provided as services over the Internet. Sharing data in a multiowner manner while preserving data and identity...

Analysis of Sandwich Beam

Sandwich beams are composite systems having high stiffness-to-weight and Strength-toweight ratios and are used as light weight load bearing components. The use of thin, strong skin sheets adhered to thicker, lightweig...

Download PDF file
  • EP ID EP16657
  • DOI -
  • Views 351
  • Downloads 9

How To Cite

P. Muni Sravani, D. Srilatha, M. Bala Subba Reddy (2015). Controller Implementation for PV Interconnection Based ThreePhase UPS Systems Operating Under Highly Nonlinear Loads. International Journal of Science Engineering and Advance Technology, 3(11), 1081-1092. https://europub.co.uk/articles/-A-16657