Convective Heat Transfer Model through Annular Finned Evaporator of a Cold Storage Using Taguchi Regression, S/N Ratio and ANOVA Analysis

Abstract

To overcome the energy crisis and increase of cost of electrical energy to operate the cold storage various design of experiments are done to optimize different control factors of a cold storage evaporator space inside the cold room. Here we have use annular fin to maximize the heat absorption by evaporator. Taguchi orthogonal array with regression analysis have been used as a design of experiments. The control factors are Area of the evaporator with annular fin(A), temperature difference of the evaporator space (dT), and relative humidity inside the cold room(RH). The Taguchi S/N ratio analysis have used as an optimization technique. Larger the better type S/N ratio have used for calculating the optimum level of control parameters, because it is a maximization problem. Analysis of variance ANOVA was also performed on the test results to find out the significant control factors.

Authors and Affiliations

Dr. N. Mukhopadhyay, Tapan Mondal

Keywords

Related Articles

Radiation Model of a Technological Pipe of Nuclear Power Plant

In This Paper, A Description Of The Model Of The Radiation State Of Anuclear Facility Is Developed And The Composition Of The Model Is Outlined.The Problems Of The Formation Of The Engineering-Radiation Model Of The Nucl...

Non-Exhaustible Solar-Power Based Insecticide or Bio-fertilizer Sprayer for Use in Agronomics (With Bluetooth Enabled Control)

Agronomics is a profession of many related sequential and sometimes concurrent tedious processes and methodologies. The Primary process among many is the spraying of insecticides, pesticides, liquefied fertilizers in the...

Melanins are Biological Diamonds

In the article the physical, chemical, biological properties, the significance and the role in Nature of melanin pigments are considered. Very long time these pigments were considered as metabolism garbage in the living...

Consumer-Based Brand Equity and Firm Risk

Investors And Managers Evaluate Potential Investments In Terms Of Risk And Return. Research Has Focused On Linking Marketing Activities And Resource Deployments With Returns But Has Largely Neglected Marketing’s Role In...

Advanced Approach for Slopes Measurement by Non - Contact Optical Technique

A numerical computation of a very advanced experimental method to acquire shapes is introduced in this paper. The basic equations that relate the measurement of slopes to the basic geometric and optical parameters of the...

Download PDF file
  • EP ID EP391496
  • DOI 10.9790/9622-0706063343.
  • Views 120
  • Downloads 0

How To Cite

Dr. N. Mukhopadhyay, Tapan Mondal (2017). Convective Heat Transfer Model through Annular Finned Evaporator of a Cold Storage Using Taguchi Regression, S/N Ratio and ANOVA Analysis. International Journal of engineering Research and Applications, 7(6), 33-43. https://europub.co.uk/articles/-A-391496