COOLING OF A PROCESSOR WITH THE USE OF A HEAT PUMP

Journal Title: Civil and Environmental Engineering Reports - Year 2018, Vol 1, Issue 28

Abstract

In this paper the problem of cooling a component, in the interior of which heat is generated due to its work, was solved analytically. the problem of cooling of a processor with the use of a heat pump was solved based on a earlier theoretical analysis of authors of external surface cooling of the cooled component by using the phenomenon of liquid evaporation. Cases of stationary and non-stationary cooling were solved as well. The authors of the work created a simplified non-stationary analytical model describing the phenomenon, thanks to which heat distribution within the component, contact temperature between the component and liquid layer, and the evaporating substance layer thickness in relation to time, were determined. Numerical calculations were performed and appropriate charts were drawn. The resulting earlier analytical solutions allowed conclusions to be drawn, which might be of help to electronics engineers when designing similar cooling systems. Model calculations for a cooling system using a compressor heat pump as an effective method of cooling were performed.<br/><br/>

Authors and Affiliations

Zygmunt LIPNICKI, Hanna LECHÓW, Katarzyna PANTOŁ

Keywords

Related Articles

THE IMPACT OF POTASSIUM MANGANATE (VII) ON THE EFFECTIVENESS OF COAGULATION IN THE REMOVAL OF IRON AND MANGANESE FROM GROUNDWATER WITH AN INCREASED CONTENT OF ORGANIC SUBSTANCES

The article presents the results of studies concerning the impact of the method of Fe(II) ion oxidisation (dissolved oxygen and potassium manganate (VII)) on the effectiveness of coagulation in the removal of iron and ma...

IMPACT OF PYRETHROIDS ON METHANE DIGESTION

The process of methane digestion is very sensitive to any changes in the environment. In the group of compounds exerting a toxic effect on the process a special notice should be taken to pesticides – agricultural chemica...

THE WATER RESOURCES OF ZIELONA GÓRA AS AN ELEMENT OF ITS SUSTAINABLE DEVELOPMENT

The subject of this paper is the presentation the water resources and water management as an example of Zielona Góra. In the paper it is shown that the water management should be recognized as the element of the sustaina...

ROAD INVESTMENT DESIGN IN AREAS PROTECTED BY THE MONUMENTS CONSERVATOR

Design works on road construction plans for areas protected by conservation require a proper preparation, especially in terms of formality, which has been described in this paper. One has shown the various methods of con...

On the tolerance averaging of heat conduction for periodic hexagonal-type composites

The paper deals periodic composites which two-dimensional material structure is determined by the anisotropic conductivity matrix invariant with respect to the pair of translations such that the periodic cell determined...

Download PDF file
  • EP ID EP345895
  • DOI 10.2478/ceer-2018-0002
  • Views 68
  • Downloads 0

How To Cite

Zygmunt LIPNICKI, Hanna LECHÓW, Katarzyna PANTOŁ (2018). COOLING OF A PROCESSOR WITH THE USE OF A HEAT PUMP. Civil and Environmental Engineering Reports, 1(28), 16-25. https://europub.co.uk/articles/-A-345895