COOLING OF A PROCESSOR WITH THE USE OF A HEAT PUMP

Journal Title: Civil and Environmental Engineering Reports - Year 2018, Vol 1, Issue 28

Abstract

In this paper the problem of cooling a component, in the interior of which heat is generated due to its work, was solved analytically. the problem of cooling of a processor with the use of a heat pump was solved based on a earlier theoretical analysis of authors of external surface cooling of the cooled component by using the phenomenon of liquid evaporation. Cases of stationary and non-stationary cooling were solved as well. The authors of the work created a simplified non-stationary analytical model describing the phenomenon, thanks to which heat distribution within the component, contact temperature between the component and liquid layer, and the evaporating substance layer thickness in relation to time, were determined. Numerical calculations were performed and appropriate charts were drawn. The resulting earlier analytical solutions allowed conclusions to be drawn, which might be of help to electronics engineers when designing similar cooling systems. Model calculations for a cooling system using a compressor heat pump as an effective method of cooling were performed.<br/><br/>

Authors and Affiliations

Zygmunt LIPNICKI, Hanna LECHÓW, Katarzyna PANTOŁ

Keywords

Related Articles

NUMERICAL ANALYSIS OF EFFECTIVENESS OF STRENGTHENING CONCRETE SLAB IN TENSION OF THE STEEL-CONCRETE COMPOSITE BEAM USING PRETENSIONED CFRP STRIPS

One of the methods to increase the load carrying capacity of the reinforced concrete (RC) structure is its strengthening by using carbon fiber (CFRP) strips. There are two methods of strengthening using CFRP strips - pas...

VIBRATION CONTROL DEVICES FOR BUILDING STRUCTURES AND INSTALLATION APPROACH: A REVIEW

Retrofit and structural design with vibration control devices have been proven repeatedly to be feasible seismic hazard mitigation approach. To control the structural response; supplemental energy dissipation devices hav...

Post-mining landscape ecology - analysis of selected problems, the case of Adamów Brown Coal basin

The paper presents the main problems of the development of post-mining area landscapes, which are due to the ignoring or including, to a small extend, the environmental criteria in the process of reclamation. It refers t...

ALGORITHM OF REVITALIZATION PROGRAMME DESIGN FOR HOUSING ESTATES

Demographic problems, obsolescence of existing buildings, unstable economy, as well as misunderstanding of the mechanism that turn city quarters into areas in need for intervention result in the implementation of improve...

Calcium content in post-mining grounds in the Łęknica region

The work contains results of a study on the calcium content – subtotal and soluble in 0.1M HCl – in post-mining grounds in Łęknica area. Subtotal content of calcium in the level of forest litter, regardless of the used f...

Download PDF file
  • EP ID EP345895
  • DOI 10.2478/ceer-2018-0002
  • Views 66
  • Downloads 0

How To Cite

Zygmunt LIPNICKI, Hanna LECHÓW, Katarzyna PANTOŁ (2018). COOLING OF A PROCESSOR WITH THE USE OF A HEAT PUMP. Civil and Environmental Engineering Reports, 1(28), 16-25. https://europub.co.uk/articles/-A-345895