Correlation between Central Venous Pressure and Inferior Vena Cava Sonographic Diameter; Determining the Best Anatomic Location

Journal Title: Archives of Academic Emergency Medicine - Year 2016, Vol 4, Issue 2

Abstract

Introduction: The correlation of central venous pressure (CVP) with inferior vena cava (IVC) sonographic diameter has been reported in several studies. However, few studies have attempted to find the best anatomic location of measurement. Therefore, the purpose of this study was determining the best anatomic location to find precise correlation between CVP and IVC diameter using transesophageal echocardiography (TEE). Methods: In the present diagnostic accuracy study, patients in need of central venous catheterization and TEE were enrolled. Maximum diameter of IVC were measured during expiratory phase of respiratory cycle at the level of diaphragm, 2cm above the diaphragm and at the point of entry into the right atrium using SonoSite TEE device. CVP was measured using an electronic transducer connected to the central venous line. The best location for sonography was determined via calculating and comparing area under the receiver operating characteristics (ROC) curve (AUC). Results: 39 patients were enrolled (53.8% female). Mean CVP was 6.8 ± 1.4 mmHg and 25 (64.1%) patients had normal CVP, while 14 (35.9%) showed elevated CVP (> 6 mmHg). Evaluating AUC showed that IVC diameter (p = 0.01), aorta diameter (p = 0.01) and IVC / aorta ratio (p = 0.004) had acceptable correlation with CVP. Point of entry of IVC into the right atrium with AUC of 0.98 (95% CI: 0.95 – 1.00) was the location of highest correlation with CVP. Conclusion: Based on the present findings, the IVC sonographic diameter and IVC / aorta ratio had acceptable correlation with CVP at the level of IVC entry into the right atrium.

Authors and Affiliations

Keywords

Related Articles

Knowledge and Attitude Regarding Organ Donation among Relatives of Patients Referred to the Emergency Department

Introduction: Organ donation is one of the surviving procedures, which can increase the life expectancy of end-stage patients. Inappropriate beliefs and attitude of individuals to organ donation, their poor knowledge, an...

Characteristics of Mortalities related to Pulmonary Embolism following Multiple Trauma; a Brief Report

Introduction: Pulmonary embolism (PE) is introduced as the third major cause of death after trauma in those who survive more than 24 hours. This study aimed to describe the characteristics of mortalities due to trauma re...

Diagnostic Accuracy of Ultrasonography and Radiography in Detection of Pulmonary Contusion; a Systematic Review and Meta-Analysis

Introduction: Ultrasonography is currently being used as one of the diagnostic modalities in various medical emergencies for screening of trauma patients. The diagnostic value of this modality in detection of traumatic c...

Applications of Machine Learning Approaches in Emergency Medicine; a Review Article

Using artificial intelligence and machine learning techniques in different medical fields, especially emergency medicine is rapidly growing. In this paper, studies conducted in the recent years on using artificial intell...

Pharyngeal Aspiration of Complete Upper Denture in 90-Year-Old Man; a Case Report

Foreign body aspiration is unusual in adults, except those who are debilitated or have neuropsychiatric disorders. It can be a life-threatening situation and it often requires a high index of suspicion, because the diagn...

Download PDF file
  • EP ID EP330226
  • DOI -
  • Views 218
  • Downloads 0

How To Cite

(2016). Correlation between Central Venous Pressure and Inferior Vena Cava Sonographic Diameter; Determining the Best Anatomic Location. Archives of Academic Emergency Medicine, 4(2), 83-87. https://europub.co.uk/articles/-A-330226