Corrosion Mapping of Water Wall Tubes of Boiler using LFET

Abstract

Corrosion of boiler tubes results in forced outage and it turns into huge loss of money. Maximum failure of water wall tubes is associated with the phenomenon of corrosion. The present paper discusses a technique for inspection of water walls before failure. Water wall tubes were inspected in situ condition by using Low Frequency Electromagnetic Technique (LEFT). Visual inspection of tubes was also carried out before scanning and it was observed that some of the tubes were bulged, eroded and having mechanical dent. During scanning signal wave forms were found not in uniform nature with respect to base line due to erosion, mechanical damage & bulging and those were recommended to be replaced.

Authors and Affiliations

Gagan Kumar Gupta

Keywords

Related Articles

Flexural Behaviour of Sugarecane Bagasse Ash Modified Fibre Reinforced Concrete

Cement is the major component in concrete. The cement industry is creating environmental problem by emission of CO2 during manufacturing of cement. There are various environmental impacts of cement on our ecology. Today...

Some Fixed Points Theorems

In this research paper we have proved a fixed point theorem by taking a function to be an upper semi-continuous function from right. This theorem uses a function from the set of all positive real numbers to itself. Thus...

SPS Gold Code Generation and Implementation for IRNSS User Receiver

The Indian Regional Navigational Satellite System (IRNSS) with Indian Constellation is an autonomous regional satellite navigation system developed by Indian Space Research Organization (ISRO). In this paper we have impl...

Doubly Fed Induction Generator Based WECS With The Double Trap LLCL Filter For Harmonics Mitigation

The wind energy conversion system integrated with a doubly fed induction generator. The PWM based back-toback power converters produced harmonic and as well as the non-linear loads are also a contributor of harmonics. Fi...

Experimental Investigations on Performance And Emission Characteristics of LHR Engine At Different Injection Timings Using Biodiesel Fuels

The reduction of heat loss from the combustion chamber of diesel engines improves fuel efficiency only by 3 or 4 per cent. Some other gains may be possible from a smaller cooling system, recovery of exhaust energy, and i...

Download PDF file
  • EP ID EP392928
  • DOI 10.9790/9622-0711062329.
  • Views 97
  • Downloads 1

How To Cite

Gagan Kumar Gupta (2017). Corrosion Mapping of Water Wall Tubes of Boiler using LFET. International Journal of engineering Research and Applications, 7(11), 23-29. https://europub.co.uk/articles/-A-392928