Credibility of locking plate in treatment of distal end radius fractures with intra articular extension

Journal Title: International Journal of Orthopaedics Sciences - Year 2017, Vol 3, Issue 2

Abstract

Background: The management of distal end radius has undergone an extraordinary evolution over the preceding twenty years. The technical advance of palmar locking plating has again changed the management of this fracture in a real and seemingly permanent way. Perhaps most importantly it is becoming increasingly apparent that operative intervention needs to be customized to the patient, fracture and expertise of the surgeon. Materials and Methods: The study is hospital based prospective study centered in R.L. Jalappa Hospital from November 2013 to April 2015 between which thirty patient patients with intra articular distal radius fractures are treated with locking compression plate and screws. Results: Patients were regularly followed-up post-operatively. Thirty cases were available for follow up. Excellent results were seen in 20 patients, good results in 5 patients, fair results in 3 patients and poor results in 2 patients. Conclusion: Open reduction and internal fixation with locking compression plate and screws gives better functional and anatomical results in intra articular distal radius fractures. The successful use of locking compression plate for intra articular distal radius fractures requires careful assessment of fracture pattern, appropriate patient selection, meticulous surgical techniques, appropriate choice of fixation, screw size, judicious augmentation with internal fixation, careful post-operative monitoring and aggressive early institution of rehabilitation. The final functional result of treatment not only depends of on anatomical reduction but also depends on surrounding soft tissue injuries and early mobilization.

Authors and Affiliations

Dr. Parvataneni Prathap, Dr. Arun HS, Dr. Buddai Nagarjun

Keywords

Related Articles

Post-operative clinical outcomes in patients with or without the use of tourniquet in total knee replacement surgery

Introduction: The use of tourniquet in a total knee replacement (TKR) has been advocated by some researchers across the globe, though the evidence is still lacking. In this study we aimed to assess the effect of using a...

Outcomes of proximal femoral nail in subtrochanteric femur fractures through medial entry

Introduction: Subtrochanteric Fractures of Femur accounts for 10-34% of all hip fractures. Several Methods of treatment of this Fractures have been reported like DHS (Dynamic hip screw), Angled blade Plate, Proximal Femu...

Functional outcome of different treatment methods in fingertip injuries: A prospective study

Background: Various treatment modalities are used from the past to treat fingertip injuries. The common methods used are suturing, skin grafting, flap coverage of the wound by different techniques. This study reports the...

Male sex preponderance in cerebral palsy

Introduction: Cerebral palsy affects 2 – 3 per 1000 live children. It is a group of movement and postural disorders due to non progressive lesion in the immature brain. There are several proposed antenatal, intra natal,...

A retrospective analysis of extra articular glenoid neck fracture of scapula (A study of 20 cases)

Introduction: Since long ago the scapula fracture is treated conservatively and most of time it works because scapula is a flat bone and coated with bulky muscle. So, nonunion of the fracture is usually not a problem, an...

Download PDF file
  • EP ID EP502241
  • DOI 10.22271/ortho.2017.v3.i2i.81
  • Views 107
  • Downloads 0

How To Cite

Dr. Parvataneni Prathap, Dr. Arun HS, Dr. Buddai Nagarjun (2017). Credibility of locking plate in treatment of distal end radius fractures with intra articular extension. International Journal of Orthopaedics Sciences, 3(2), 774-778. https://europub.co.uk/articles/-A-502241