Cyclic Fatigue Resistance of Biorace Nickel-titanium File with Variable Taper after Immersion in Sodium Hypochloride

Journal Title: Bezmiâlem Science - Year 2021, Vol 9, Issue 1

Abstract

Objective: This study aimed to evaluate the effect of sodium hypochlorite on the cyclic fatigue resistance of BioRace (BR) files according to taper. Methods: BR 25.04 and 25.06 files were divided into the following groups: group 1, 20 BR 25.04 with no immersion in NaOCl; group 2, 20 BR 25.04 with immersion in 5.25% NaOCl at 37 °C ±1 °C for 5 min; group 3, 20 BR 25.06 with no immersion; and group 4, 20 BR 25.06 with immersion in 5.25% NaOCl at 37 °C ±1 °C for 5 min. The instruments were applied to a stainless-steel artificial root canal of 60° curvature and 5-mm radius. The time to failure (TTF) in seconds and number of cycles to failure (NCF) were recorded. Results: The cyclic fatigue resistance of BR 25.04 was significantly higher than that of BR 25.06. The TTF and NCF values were significantly higher in group 1 than in groups 2 and 3 and in group 2 than in group 4. However, neither value differed significantly between groups 3 and 4 (p>0.05). Conclusion: Taper and sodium hypochlorite affected the cyclic fatigue resistance of BR.

Authors and Affiliations

Burçin ARICAN, Ayfer ATAV ATEŞ

Keywords

Related Articles

The Effects of Camellia sinensis Extract on Proliferation, Apoptosis and Oxidative Stress in Insulinoma INS-1 Cells

Objective: Green tea (Camellia sinensis) is one of the most consumed beverages in the world. C. sinensis consumption may prevent tumor and other diseases. Insulinomas are pancreatic islet cell tumors. In present study, t...

Frameless Neuronavigation Assisted Brain Biopsy: Safety, Efficiency and Our Experience

Objective: Brain biopsy is a commonly used method for diagnosing deeply located or generalized intraparenchymal brain lesions and determining the further treatment options. A number of comparative studies have been perfo...

The Value of Magnetic Resonances Imaging in Localized Lipoatrophy

Localized lipoatrophy usually presents as isolated or multiple, atrophic, depressed areas which are commonly found in the proximal part of extremities. We report a case with idiopathic localized lipoatrophy and want to e...

Download PDF file
  • EP ID EP691825
  • DOI 10.14235/bas.galenos.2020.3918
  • Views 130
  • Downloads 0

How To Cite

Burçin ARICAN, Ayfer ATAV ATEŞ (2021). Cyclic Fatigue Resistance of Biorace Nickel-titanium File with Variable Taper after Immersion in Sodium Hypochloride. Bezmiâlem Science, 9(1), -. https://europub.co.uk/articles/-A-691825