Data Center: Energetic and Economic Analysis of a More Efficient Refrigeration System with Free Cooling and the avoided CO2 Emissions

Abstract

The use of air conditioning equipment is becoming more frequent, and new technologies are emerging to increase the efficiency of the process and decrease the operating costs of air conditioning systems. In data centres, where electric power consumption is high and indoor cooling is a constant, the air conditioning systems are responsible for a large part of the building's energy consumption. In this work, a data centre with a twenty years old cooling system (with production of chilled water - CW), was analysed and is about to be replaced. In order to meet the thermal load of the building, two solutions were proposedwith a more efficient refrigeration system: one with production of chilled water (case 1) and another one with a direct expansion system (DX, case 2). It was also analysed the possibility to use free cooling in both of them. In both cases the results obtained shows a significant reduction on the energy consumption and consequently a reduction in the CO2 emissions, regarding the old system. An economic analysis was also carried and the conclusions were that they are profitable. The final decision is due to the customer.

Authors and Affiliations

Clito Afonso, João Moreira

Keywords

Related Articles

Meaning of Law 9.610/98 Based on Grounded Theory

The Law implies both the intentionality of its writing, because it is always the result of the need to discipline activities or behaviors, as well as in the interpretation given to it. So why not interpret the Law with a...

Holistic Approach Towards Inclusive Understanding of Quality of Service In Wireless Sensor Network

Data is being communicated over a traditional network since a very long time and too much research and development has been carried out in the past. The Wireless communication is very different from that of the tradition...

Design and Implementation of Schmitt Trigger using Operational Amplifier

A Schmitt trigger is an electronic circuit, a Comparator that is used to detect whether a voltage has crossed over a given reference level. It has two stable states and is very useful as signal conditioning device. Whe n...

Evaluation Of Bituminous Mix Parameters With Addition Of Plastic Waste

Road construction is the main integral part of the developing countries. The conventional method has been proven perfect for the road construction but now, time has come where there is a need of enhancement of properties...

Big Data Science and Its Applications in Biomedical Research and Healthcare: A Review

There is a consensus among scientists that the analysis of Big Data in health care (such as electronic health records, patient reported outcomes or in motion data) can improve clinical research and the quality of care pr...

Download PDF file
  • EP ID EP392950
  • DOI 10.9790/9622-0711070612.
  • Views 69
  • Downloads 0

How To Cite

Clito Afonso, João Moreira (2017). Data Center: Energetic and Economic Analysis of a More Efficient Refrigeration System with Free Cooling and the avoided CO2 Emissions. International Journal of engineering Research and Applications, 7(11), 6-12. https://europub.co.uk/articles/-A-392950