DC Bias in Transformers of Dual Current Power Supply Lines

Journal Title: Urban Mass Transit - Year 2025, Vol 28, Issue 2

Abstract

[Objective] To ensure the safety of traction transformers in dual current power supply lines and prevent issues such as transformer vibration and winding temperature increase caused by excessive DC bias current, which can lead to severe distortion of excitation current, it is essential to study the degree of DC bias in transformers of dual current power supply lines. [Method] The DC bias problem in transformers of dual current power supply lines is introduced. By dividing the line into smaller sections, with trains in the DC segment modeled as power sources, and trains in the AC segment and traction transformers modeled as resistances, a chain-circuit model for the dual current power supply system is established. Using continuous linear load flow calculation method, the DC bias current of transformers in the AC segment of a dual current power supply line is computed. The calculated results are compared with field-measured data to verify the validity and accuracy of the proposed method. [Result & Conclusion] The DC bias current in transformers significantly exceeds the standard at certain times. The proposed calculation method, characterized by minimal admittance matrix order and fast computation speed, is suitable for dynamic calculations of DC bias currents in transformers of dual current power supply lines.

Authors and Affiliations

Xuefei LI, Wenbin SUN, Chao GUAN, Jun DAI, Wei LIU

Keywords

Related Articles

Empirical Research on Urban Rail Transit and Urban Economic Low-carbon Transformation

[Objective] Urban rail transit system is an important part of modern urban economy. To better realize the low-carbon transformation of urban economy, attention should be given to the impact of urban rail transit system o...

Study on Stability of Small Clearance Shield Tunnel Excavation Face

[Objective] Determine the limit support pressure required to maintain tunnel face stability during the construction of double-line small clearance shield tunnel. [Method] The excavation stability of double-line small...

Signaling System Retrofit and Reverse-connection Scheme for Shanghai Rail Transit Line 13 Beidi Road Depot

Objective Beidi Road Depot of Shanghai Rail Transit Line 13 is undergoing an upgrade from a conventional interlocking system to CBTC (communication-based train control) system. This upgrade is characterized by a short ni...

Fault Diagnosis Method for Control Circuit of ZDJ9 Double-machine Traction Speed-up Turnout Electric Switch Machine

[Objective] In the ZDJ9 double-machine traction speed-up turnout electric switch control circuit, 1DQJ is an instantaneous suction relay. When the outdoor switch circuit does not form a loop, that is, in the event of a...

Study on Stiffness Characteristics of Rubber Springs for Rail Vehicles Based on Different Constitutive Models

[Objective] The structure of rubber spring shock absorbers for rail transit is complex, its stiffness characteristics are mainly predicted by simulation methods, but simulation results of different constitutive models...

Download PDF file
  • EP ID EP759802
  • DOI 10.16037/j.1007-869x.2025.02.005
  • Views 28
  • Downloads 0

How To Cite

Xuefei LI, Wenbin SUN, Chao GUAN, Jun DAI, Wei LIU (2025). DC Bias in Transformers of Dual Current Power Supply Lines. Urban Mass Transit, 28(2), -. https://europub.co.uk/articles/-A-759802