Definition of a composite index of glazing rooms

Abstract

<p>The effect of geometrical parameters of rooms and window openings on the value of the daylight factor (DF) in the reference point on the work surface is considered in the article. This is important, as while using a light factor (LF) and a window-to-wall ratio (WWR), there is a significant error. Therefore, there are objective difficulties with the unification of the results of studies on the effectiveness of natural sidelight, which are due to the influence of the size of the room on the DF value in the reference point on the work surface.</p><p>The use of the above-mentioned coefficients to evaluate the efficiency of lateral natural light results in the fact that, at constant value of the coefficient, the value of the DF may differ several times. This is because the area of the window opening does not correspond to the area of glazing through which daylight passes into the room. The area of the room does not correspond to the area of the work surface on which it is necessary to provide normalized illumination, and the dimensions of both the room and the work surface are not taken into account in the LF or in the WWR at all.</p><p>It is proposed to use a composite room glazing index (CRGI). It takes into account not only the glazing area of the window opening but also the dimensions and area of the work surface. This makes it possible to use the results of studies on the effectiveness of natural light without binding them to the dimensions of a room. Using the Relux program, the DF value in the reference point for rooms of different sizes with different glazing areas of the window openings is calculated and the dependence of the DF on the CRGI has been obtained. As a result of the approximation of this dependence, an equation describing the relationship between these quantities has been developed.</p>An algorithm that takes into account both the width of the opaque portion of the window opening and its proportion has been developed to determine the area of the window opening at which the required value of the DF in the reference point is provided. The obtained scientific result in the forms of the CRGI and algorithm of calculating the area of the window opening is interesting from the theoretical point of view. From a practical point of view, the results help calculate the minimum glazing area of the window opening to provide a normalized DF value with a standard deviation of 0.894, based solely on the dimensions of the room. This is a prerequisite for using the obtained results in the development of normative documents for construction sites

Authors and Affiliations

Vitalii Burmaka, Mykola Tarasenko, Kateryna Kozak, Viktor Khomyshyn

Keywords

Related Articles

Preservation of parsnip root vegetable depending on the degree of ripeness, varietal features, and storage techniques

<p>The degree of ripening of vegetables, fruits and berries affects their preservation. It is not possible to detect the degree of ripening of parsnip by the size of a root crop, since growing conditions and agricultural...

Development of structures of the aircraft fire alarm system by means of nested modules

<p>Optimization of structures of information management systems is determined by the choice of such a functional structure that would ensure high reliability of information. When creating complex systems, there is the pr...

Studying the influence of uv adsorbers on optical characteristics of light-protective polymer films for textile materials

<p>The use of UV adsorbers included in composition of a polymer film is a promising way of color protecting against effects of light since application of the polymer to the textile material surface is a universal way of...

Construction of models for estimating the technical condition of a hydrogenerator using fuzzy data on the state of its local nodes

<p>The task on estimating the technical condition of a hydrogenerator under conditions of fuzzy information has been resolved. To this end, a series of models have been constructed for the integrated estimation of the te...

A study of the effects of climatic temperature changes on the corrugated structure

<p>The study provides the results of experimental tests on temperature distribution throughout the surface of a corrugated metal sheet.</p><p>Mathematical models are proposed for calculating the thermal conductivity and...

Download PDF file
  • EP ID EP528117
  • DOI 10.15587/1729-4061.2018.141018
  • Views 55
  • Downloads 0

How To Cite

Vitalii Burmaka, Mykola Tarasenko, Kateryna Kozak, Viktor Khomyshyn (2018). Definition of a composite index of glazing rooms. Восточно-Европейский журнал передовых технологий, 4(10), 22-28. https://europub.co.uk/articles/-A-528117