Design and Analysis of Water Hammer Effect in a Network of Pipelines

Abstract

There will be a chance for the destruction of the system due to transient if it is not provided with adequate protection devices. Generally, transient takes place when parameters involving in conventional flow are distorted with respect to the time. Rapid closing of valve in a pipe network will be resulting into hydraulic transient known as water hammer occurs due to sudden change in pressure and velocity of flow with respect to time. Due to impulsive action, pressure surges are induced in the system travel along the pipe network with the rapid fluid acceleration leading to the dramatic effects like pipe line failure, damage to the system etc. Considering the importance of hydraulic transient analysis, we design a system capable of verifying pipe network containing fluid flow.This paper demonstrates design of different pipe structures in pipe line network and analysis of various parameters like excess pressure distribution, velocity variations and water hammer amplitude with respect to time using COMSOL Multiphysics v 4.3. The magnitude of water transient in pipe line network at different pressure points has been discussed in detail.

Authors and Affiliations

V. Sai Pavan Rajesh

Keywords

Related Articles

slugManufacturing of 64-Bit Vliw Microprocessor

In the two decades since FPGAs introduced, the way which digital logic is designed and deployed has been radically changed. FPGAs have made possible entirely new types of applications. It is very important to design mi...

Study of Pedestrian Safety and Accident Analysis on Chennai City

Each year, more than 270 000 pedestrians lose their lives on the roads. Globally, pedestrians constitute 22% of all road traffic fatalities, and in some countries this proportion is as high as two thirds of all road tra...

Frequency Oscillation & Power Oscillation Damping Controlled by PSO Tuned SSSC Controller

Today’s modern interconnected power system is requiring operating stability consideration. Reliability and stability is key issue of modern power system .power and frequency oscillation damping mechanism is requiring pr...

A GSM Based Embedded Mobile Web Server for Monitoring Aged People

Now a day’s many real time applications are connected to web(internet).This is very useful and helpful for customers to see application(requirements) from anywhere in the world. These web connected applications belong t...

Adaptive Noise Canceller

Adaptive Noise Cancellation is an alternative technique of estimating signals corrupted by additive noise or interference. Its advantages lies in that, with no prior estimates of signal or noise, levels of noise rejecti...

Download PDF file
  • EP ID EP18812
  • DOI -
  • Views 328
  • Downloads 10

How To Cite

V. Sai Pavan Rajesh (2014). Design and Analysis of Water Hammer Effect in a Network of Pipelines. International Journal for Research in Applied Science and Engineering Technology (IJRASET), 2(9), -. https://europub.co.uk/articles/-A-18812